Technical Specifications - VONROC MARSILI COMPACT Traduction De La Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
EN

TECHNICAL SPECIFICATIONS

Model No.
Voltage
Frequency
Power
Heating element type
Heating time
Wave length
Radiant efficiency
Heating distance
Heating area
Colour temperature
Electronic soft start
Ingress protection class
Protection class
Weight
DESCRIPTION
The numbers in the text refer to the diagrams on
page 2-5.
1. Heater
2. Protective grill
3. Power cable
4. On/off switch
5. Mounting bracket
6. Sleeve anchor
7. Screw with washers
8. Wing nut
9. Bolt
10. Washer
3. ASSEMBLY
This heater should be installed by a
competent person, i.e. a qualified electrician.
Always disconnected the heater from the
electrical supply and allow it to cool before
installation.
Installing the heater (Fig. A­N)
Always mount the device with the supplied
accessories.
8
PH506AC
220–240 V ~
50-60 Hz
2000W
Low glare lamp
1 second
0.78-1.4 microns
90%
4-5m
10-12m²
1500K
Yes
IP55
Class I
1.60 kg
Before starting the installation, take the following
into consideration:
• Place the device on a firm, level surface.
• The device must be mounted so that there is
50 cm of free space between the heater and
any ceiling, tent canvas etc. There must also
be at least 1.80 m between the ground and the
underside of the device. Refer to Fig. J and K.
The device may never be hung at an angle!
• Ensure that the power supply cable is well
mounted and that it does not come into contact
with reflector of the heater or that does not trail
into heated area.
• Do not install the heater on an inflammable
surface.
• If the heater is to be used outside, a weather-
proof outlet is highly recommended.
• Before drilling ensure that there are no wires or
water pipes in the area where the heater is to
be installed.
To install the heater on a wall or ceiling, follow
these steps:
1. The device is supplied with the mounting acces-
sories as shown in figure C.
2. Drill a total of 4 holes using the dimensions in
figure D. The hole diameter should be the same
diameter as the anchor diameter: 8mm. Drill at
least 10 to 15 mm deeper than the expected
embedment. Ensure the holes are level and at
exactly the same height.
3. Clean out the holes of any debris.
4. Set the nut flush with the top of the sleeve
anchor (6), shown as step 1 in figure E.
5. Insert the sleeve anchor (6) into the hole in
the base material, shown as step 2 in figure E.
Using a hammer, insert the sleeve anchor as far
until the washer and nut are tight against the
base material.
6. Now put the mounting bracket (5) on the sleeve
anchors (6), and mount it using the washer
and nut. Turn the nut until finger tight. Both as
shown on figure F.
7. Use a size 10 wrench to set the anchor by turn-
ing the nut three to four full turns.
8. Mount the remaining 2 mounting brackets (5)
onto the outer holes of the heater (1), as shown
on figure G.
9. Take the heater with the assembled brackets
to the mounting brackets mounted on the wall
or ceiling. Now pair both brackets with the bolt
WWW.VONROC.COM