SPIT TRIX 160 Notice D'emploi Et D'entretien page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
3) Fit the quick-fastening screw, then place the base plate over the screw and align
the stand assembly using the fastening slot.
4) Fit the washer and the quick fastening nut and tighten the nut using a 32 mm
spanner.
5) Before and after tightening the nut, carefully level the stand using the three levelling
screws and firmly tighten the 3 levelling screws.
3
CHECK TO ENSURE THAT THE RIG IS PROPERLY SECURED!!
For fastening to a material other than concrete, please contact us regarding the
selection of a suitable anchor plug.
Vacuum fastening (maximum Ø 130 mm)
For this type of fastening, the material to be drilled must be smooth and flat, non-porous
and free from cracks and reinforcements.
The maxiumum diameter to be drilled is 101 mm.
This type of fastening cannot be used if these conditions are not met.
For vacuum fastening, you must use a Spit vacuum pump and a Spit vacuum kit with
manometer and seal (1).
Consult the manual of the vacuum pump regarding the use and maintenance.
2) Put the plate in the foreseen place on the back of the vacuum plate and fix the
hexagonal nut.
3) Put the seal in the foreseen place.
1
4
5
2
3
GB
3

Publicité

Table des Matières
loading

Produits Connexes pour SPIT TRIX 160

Table des Matières