During the operation with timer, the respective display of the operating time also changes. After the time has already
elapsed (1 hour, 2 hours, 3 hours, 4 hours, 5 hours, 6 hours, 7 hours), the display changes to the respective remaining
time. When the timer has expired, the device switches off automatically.
While the timer is activated, all other functions of the device can still be used and set. The timer remains unaffected.
Child lock
Press the child lock button
the remote control can now be pressed. To switch off the child lock, press the child lock button again. The child lock can
only be controlled with the remote control.
CHANGE FILTER:
CAUTION
Before changing the filter
any voltage source.
For optimal air quality, the filter should be changed approximately every 3 - 6 months, depending on usage. To change
the filter
, proceed as follows:
2
1. Press left and right into the lower sides of the front cover
and open it by pulling the front cover
2. Remove the front cover
3. Remove the old filter
the fabric flaps of the new filter are facing outwards.
4. Hook the front cover
housing until you hear a click.
You can purchase a suitable filter from Schwaiger under article number 658040.
TROUBLESHOOTING:
Description of error
Device isn't working
The air quality is not good, the sensor still
lights up blue
Bad odors can be removed only with great
difficulty / device makes loud noises
Technical data
Item number
Power supply
Rated Power
Maximum air flow
CADR
Anions concentration
UV-Wavelength
Cable lenght
Dimensions
Weight
on the remote control to switch on the function. No buttons on the control panel
23
, make sure that the mains plug
2
away.
4
.
4
and insert the new one in the same orientation. When inserting the new filter, make sure that
2
back into the housing from above and then press the lower part of the cover firmly into the
4
Check solutions
Is the power plug connected correctly?
 Insert the mains plug into a suitable socket.
Has the unit been properly assembled after cleaning/filter change?
 Assemble all serviceable parts of the unit correctly.
Have you placed the device in a place where little air gets in?
 Place the device in a suitable, well-ventilated location.
The sensor requires approx. two minutes lead time to be able to mea-
sure the air quality. Wait briefly and then check the air quality again.
Device or filter are not free?
 Clean the device and remove any dirt from the filter. If the problem is
is disconnected and the unit is no longer connected to
13
to release the latch. Press and hold the lock on both sides
4
still not solved, replace the filter.
658019
220 – 240 V
60 W
330 m³/h
240 m³/h
200.000.000 / cm³
254 nm
1,8 m
350 x 180 x 465 mm
5.400 g
14
, 50 Hz