Technical data

Housing: plastic
Protection type: IP 20 (EN 60529)
Ambient temperature: 0 ... 40 °C
Dimensions: 95 × 70 × 25 mm
Mounting: wall mounting is possible (optional)
Display:
1 bi-coloured LED at the front of the housing
2 LEDs at the RJ45 LAN connection
Power supply:
mains adapter power supply: 100 ... 240 V~ / 50-60 Hz
interface adapter power supply: 12 V ⎓ / 1 A 5.5 × 2.1 mm
Data interface: RESOL VBus
VBus
®
/LAN V2
Made in Germany
Input: 12V
/ 1 A
-
+
5.5 x 2.1 mm
14
®
, LAN interface
2

Mounting

The unit must only be located in dry interior rooms. It
is not suitable for installation in hazardous locations. The
interface adapter is light and small enough to not require
any form of mounting. It can be placed directly on the desk
or on a system component (pay attention to the allowed
ambient temperature!).
4 self-adhesive, skid-proof rubber pads are included with
the adapter. If necessary, these can be affixed to the corre-
sponding molds on the base part of the housing to ensure
a secure placement of the device without wall mounting.
If desired, the interface adapter can be mounted to a wall:
Î Mark the desired hanging position on the wall.
Î Drill and prepare the hole with a wall plug and screw.
Î Hang the device onto the screw.
Î Mark the position for the mounting screw (centres
70 mm).
Î Drill and prepare the hole with a wall plug.
Î Hang the device and fasten it by means of the second
screw.