6
Photo Receptacle
IMPORTANT
Check whether it concerns an AC(Alterna ng Current) based or DC(Direct Current) based system.
ELECTRICAL CONNECTIONS - 100-240V/277V AC, 50/60Hz
STEP 1:
Make the following Electrical Connec ons:
a.
Connect INPUT GROUND conductor to "G" posi on
of the terminal block.
b.
Connect INPUT VOLTAGE conductor to "L" posi on
of the terminal block.
c.
Connect INPUT NEUTRAL conductor to "N" posi on
of the terminal block.
STEP 2:
Make sure all excess input wires are pushed into pole, screws are
ghtened.
STEP 3:
Close cover by firmly pushing cover towards fixture, making sure
that no wires are pinched and Sealing gasket are fully engaged.
STEP 4:
If the fixture without a surge protector, please insulate all electrical
connec ons with wire nuts suitable for at least 90°C
The light source contained in this luminaire shall only be replaced by the manufacturer or
his service agent or a similar qualified person.
Cau on, risk of electric shock
This marking indicates that this product should not be disposed with other household wastes throughout the EU.
To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return your used device, please use
the return and collec on systems or contact the retailer where the product was purchased. They can take
this product for environmental safe recycling.
PHOTO CONTROL (OPTIONAL)
If the fixture with PHOTO CONTROL func on, the Photo Receptacle will be installed on
the cover of fixture. See
insert and rotate Photo Sensor to proper posi on.
<Verifying>
Make sure all the connec ons done and photo control is well installed on the fixture,
switch on the power supply and cover the window of photo sensor, wait 5 seconds, the
Photo Sensor
fixture will be turned on.
6
. Fit the pins of Photo Sensor to Photo Receptacle, firmly
Input cable should be at least H05RN-F 3x1.0mm²(SJTW 18AWG) or
outdoor grade cable with rubber sheathed(not supplied). The cable
must have a minimum cross sec onal area of 1.0mm²(18AWG).
FIXTURE WIRING
N
G
L
*If the fixture with built-in dimming func on, please connect INPUT
POSITIVE(+) signal conductor to DIM+ (PURPLE WIRE), INPUT NEGATIVE(-)
signal conductor to DIM-(GREY WIRE) of LED driver.
Class I BASED
N
LED Driver
L
V
V
in
out