Operation and Maintenance Manual Manuel d’installation et d’entretien Model No. IX800 Indirect Construction Heater Radiateur de construction indirecte 800,000 Btu/h WARNING AVERTISSEMENT Read and follow all installation, and Lisez et suivez toutes les installation et les operating instructions before first use of this...
Page 2
IX800 Operation & Service Manual GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater, can result in death, serious bodily injury and property loss or damage from hazards of fire, explosion, burn, asphyxiation, carbon monoxide poisoning, and/or electrical shock.
Page 3
IX800 Operation & Service Manual Read this Warning First Lire cet avertissement en premier Le radiateur est conçu et approuvé aux fins This heater is designed and approved for use d’utilisation comme radiateur de construction as a construction heater under ANSI Z83.7/ en conformité...
Page 4
IX800 Operation & Service Manual WARNING Air Quality Hazard • Do not use this heater for heating human living quarters. Use of direct-fired heaters in the construction environment can result in exposure to levels of CO, CO2, and NO2 considered to be hazardous to health and potentially life threatening.
Page 5
IX800 Operation & Service Manual AVERTISSEMENT Danger lié à la qualité de l’air ■ Ne pas utiliser cet appareil pour chauffer des logements humains. ■ L’utilisation d’appareils à chauffage direct dans un environnement de construction peut entraîner l’exposition à des niveaux de CO, de CO2, et de NO2 considérés nocifs pour la santé...
IX800 Operation & Service Manual Installation Installation The Sure Flame Model IX800 is an Le modèle Sure Flame IX est un radiateur indirect-fired gas heater intended to be au gaz à combustion indirecte prévu pour used primarily for the temporary heating of être utilisé...
Page 9
Propane Installation Code, CSA B149.1. propane. Ducting Conduits The IX800 can be ducted on both the inlet Le radiateur IX800 peut être canalisé à l’orifice and outlet. The inlet duct can be up to 50’ of d’entrée et de sortie. La canalisation d’entrée peut atteindre jusqu’à...
Page 10
IX800 Operation & Service Manual Venting Ventilation Cet équipement exige une ventilation vers This equipment requires Category I venting l’extérieur de Catégorie I. Le raccord d’évent to the exterior. The vent connector should devrait être conçu pour une pression négative be designed for a negative pressure and be et construit de matériaux ayant une résistance...
Page 11
IX800 Operation & Service Manual INSTALLATION USING A PROPANE SUPPLY TANK 1 When installing the heater for use with propane gas, set the gas selector valve to “Propane” and lock in position. 2 Arrange the propane supply system to provide for vapour withdrawal from the operating container.
Page 12
IX800 Operation & Service Manual IX410 Operation & Service Manual LPG - PROPANE FUEL VAPORIZATION RATE The following chart shows the amount of BTU's that various sizes of tanks will produce on the average at specific temperatures and regular atmospheric conditions.
IX800 Operation & Service Manual Operating Instructions 1) Set GAS SELECTOR VALVE to gas being used. NOTE: The Selector Valve must be locked in position. NATURAL GAS PROPANE 2) Ensure firing valve (manual valve nearest the burner) is in the “ON” position.
Page 14
IX800 Operation & Service Manual Maintenance Warning: Disconnect gas and electrical supplies before servicing. Heater should be inspected before each use and at least annually by a qualified service person. Weekly: Gas Hose Check for cracks and damaged connectors Air flow...
IX800 Operation & Service Manual Entretien Avertissement : Débrancher les alimentations en gaz et en électricité avant d’effectuer l’entretien. Le chauffage doit être inspecté avant chaque utilisation et au moins une fois par an par un technicien qualifié. Toutes les semaines : Tuyaux de gaz Vérifier s’il y a des fissures et des raccords endommagés...
Page 16
IX800 Operation & Service Manual Lubricating Bearings: Warning: Disconnect power before servicing bearings. The main blower has two bearings. They need to be periodically lubricated according to the schedule below. Some situations may require a change in lubricating periods as dictated by experience.
Page 17
IX800 Operation & Service Manual Troubleshooting The troubleshooting section has been divided in to five tables. Choose the appropriate table from the list below: Chart A – Burner blower does not start, No spark, No Flame, Chart B – Burner blower starts, No spark, No flame, Chart C –...
Page 18
IX800 Operation & Service Manual Heater Troubleshooting Burner blower does not start, no spark, no flame Symptom Possible Problems Ignition controller error light on steady. Ignition controller failure. Steady Green light is on. Single flash of the error light Air switch failure.
Page 19
IX800 Operation & Service Manual Burner blower starts, no spark, no flame Symptom Possible Problems Single error light flash on ignition Air switch failure. controller after 30 seconds. Air switch set to too high a pressure. Air tubes plugged or installed in wrong air switch position.
Page 20
IX800 Operation & Service Manual Burner blower starts, spark, flame goes out after four seconds Symptom Possible Problems Three error flashes on ignition controller. Bent flame rod. Flame turns off after 4 sec TFI. Wet flame rod. Cracked flame rod ceramic insulator.
Page 21
IX800 Operation & Service Manual Other problems during operation Symptom Possible Problems Main blower fan takes a long time to start. Top RTD or RTD controller-related Possible exchanger damage. failure.* Burner turns off shortly after it’s turned on. Side fan/limit switch failure.
Page 22
IX800 Operation & Service Manual Inlet pressure drops under 7”. Valve train Propane tank too small to vaporize pressure below nominal value. Heater ignites fast enough or tank freezes. but shuts off after awhile. Three error flashes Low inlet pressure.
IX800 Operation & Service Manual Tableau de dépannage Le ventilateur du brûleur ne s’allume pas, aucune étincelle, aucune flamme Symptôme Problème possibles Témoin d’erreur solide sur la commande Défaillance de la commande Solide d’allumage. d’allumage Témoin vert allumé. Clignotement simple du Défaillance du commutateur de...
Page 24
IX800 Operation & Service Manual Le témoin vert reste éteint lorsqu’on appuie Contact à la phase L2/L3 3 sur le bouton démarrer. Il y a du courant ou la phase L/N 1 pendant la électrique au niveau du variateur de défaillance du commutateur...
Page 25
IX800 Operation & Service Manual Le ventilateur du brûleur s’allume, étincelle, aucune flamme Symptôme Problème possibles Le moteur du brûleur démarre, mais il Défaillance de RTD en haut ou du n’y a pas de flamme après la prépurge contrôleur de RTD.* de 30 secondes.
Page 26
IX800 Operation & Service Manual Le brûleur s’allume, mais le ventilateur principal ne démarre pas Symptôme Problème possibles Code d’erreur sur le variateur de fréquence. Défaillance du variateur de Communiquer avec le fabricant. fréquence. Le brûleur se met en marche, mais le moteur Faible tension (longue rallonge du ventilateur principal ne peut pas accélérer à...
Page 27
IX800 Operation & Service Manual Autres problems pendant le fonctionnement Symptôme Problème possibles Le ventilateur principal prend beaucoup de Défaillance de RTD en haut ou du temps à se mettre en marche. Dommages contrôleur de RTD.* possibles à l’échangeur. Le brûleur s’arrête peu de temps après être Défaillance de RTD latéral ou du...
Page 28
IX800 Operation & Service Manual Le radiateur s’arrête ou le radiateur Tuyau de gaz trop petit, trop long s’enflamme, mais s’arrête peu de temps ou bloqué. après. Le témoin d’erreur de la commande d’allumage clignote trois fois. Le radiateur se met immédiatement en Défaillance du relais (2) de...
Page 29
IX800 Operation & Service Manual IX800 Wiring Diagram L.BLU L.BLU Heater 230V 115V Transformer Heater 230V Relay 1 Relay 2 IX-5807 230V Preheat Thermostat 0°C Thermostat 30°C (NO below 0°C) (NO below 30°C) L.BLU Timer (Turn ON after 12 min) Blower Motor 1Ø...
Page 30
IX800 Operation & Service Manual IX800 Ladder Diagram IX800 Ladder Diagram 208/230V 208/230V 3Ø 1Ø Power Selector Switch 3Ø Blower Motor Burner Motor Tilt Switch Fuse Burner Motor T3.5A 1Ø Relay Contact 115V 115/230V Fan Thermostat Preheat Thermostat (close above 85°F) (close above 35°F)
Page 31
IX800 Operation & Service Manual Parts Breakdown Main Blower Ref # Part # Description Ref # Part # Description IX-5794 Blower Shroud 3500 Split Taper Bushing IX-5259 Shroud Top Cover 1043 Blower Sheave 9552 Motor 7.5 HP 1046 Blower 1044...
Page 32
IX800 Operation & Service Manual Burner Ref # Part # Description Ref # Part # Description IX-3561 Burner Housing IX-3751 Burner Pipe Assembly 9823 Terminal Block IX-3157 Burner Head 8676 Ignition Transformer IX-3198 Burner Gasket 7724 Flexible Seal 3.3’ WR8GRR-33 Ground Wire...