Réservoir de dilatation chauffe-eau

Publicité

Les langues disponibles

Les langues disponibles

Safety
READ AND FOLLOW
SAFETY INSTRUCTIONS!
This is the safety alert symbol. When you see
this symbol on your pump or in this manual,
look for one of the following signal words and be alert
to the potential for personal injury!
warns about hazards that will cause
serious personal injury, death or major property
damage if ignored.
warns about hazards that can cause
serious personal injury, death or major property
damage if ignored.
warns about hazards that will or
can cause minor personal injury or property damage if
ignored.
The label NOTICE indicates special instructions which
are important but not related to hazards.
Carefully read and follow all safety instructions in this
manual and on pump and tank.
Keep safety labels in good condition.
Replace missing or damaged safety labels.
1. Read this manual carefully. Failure to follow these
Instructions could cause serious bodily injury and/
or property damage.
2. Consult installer or licensed plumber for correct
relief valve. Install system according to local codes.
3. Before installing or replacing tank, BE SURE pump
electric power source is disconnected. Release all
water pressure before working on tank or system.
4. Install a relief valve in pump supply line to tank, as
close to tank as possible.
5. BE SURE the pump electrical circuit is properly
grounded.
6. Remove bleeder orifices, air volume controls or
other air charging devices in existing system.
7. DO NOT USE tank as a surge suppressor.
Hazardous pressure. To prevent
possible serious or fatal injury and/or damage to
equipment, system pressure must be less than 150
pounds per square inch (PSI) (1,034kPa) under any
circumstances. Failure to follow instruction can result
in tank blowup. If system discharge pressure can
exceed 150 PSI (1,034kPa), install a relief valve
capable of passing the full pump volume at 150 PSI
(1,034kPa).
Do not allow pump, tank, or piping system to freeze.
Freezing can severely damage equipment and may
lead to tank explosion and serious injury. Allowing
tank to freeze voids tank warranty.
Temperature of water cannot exceed 200˚F (93˚C).
For use in non-potable residential
closed hydronic water heating systems only.
PRODUCT PRECAUTIONS
This product is designed for water storage at 200
degrees Fahrenheit and 150 PSI.
Do not exceed 80 PSI pre-charge pressure in this
tank.
The pressure relief valve must be sized and
installed according to Local Plumbing Codes and
must be set at 150 PSI maximum.
Since the tank may eventually leak, make sure not
to install without adequate drainage provisions.
Always observe local plumbing codes. This
equipment must be installed and/or serviced by
qualified professionals only.
Manufacturer does not accept any liability or
other responsibility for personal injury or property
damage resulting from improper use, wrong
installation and/or operation of this product or the
system where it is installed.
Initial under-sizing or increasing temperatures
from original settings may cause tank structure
damage and/or internal coating damage.
Exceeding the recommended temperature and
pressure limits for this product voids any and all
warranties.
2