Kathrein VOS 32/RA-1G Mode D'emploi page 6

Amplifi cateur de raccordement domestique

Publicité

Les langues disponibles
  • FR

Les langues disponibles

House connection amplifi ers
Features
House connection amplifi ers for
modern HFC networks up to 1 GHz
Integrated high-effi ciency switched-mode power supply
unit
Power management: Unused amplifi er
stage switch-off
for reduced power consumption
Die-cast housing with F-type connectors
Variable 6 dB interstage gain setting
using on-board plug-in attenuators
(delivery condition: higher gain)
The maximum operational levels also apply for
operation with interstage attenuation
Interstage equaliser switchable with bridging plugs
(6 dB pre-emphasis)
Integrated return path 5-65 MHz active/passive, off
(switchable with bridging plugs)
Built-in variable attenuators (delivery condition return
path: max. attenuation) and variable equaliser
LED to indicate operational mode
Basic safety precautions
• Installation must be carried out by authorised specialist staff.
• Unplug from the mains before installation.
• Described amplifi ers are exclusively for installation of HFC networks up to 1,006 MHz.
• Any other use or failure to comply with these instructions will void the warranty or guarantee.
• The amplifi ers may only be installed in dry areas indoors. Do not install on or against highly combustible
materials.
• The amplifi ers must be earthed when installed (Cu, minimally 4 mm²).
• The safety regulations set out in the current EN 60728-11 and EN 60065 standards must be complied with.
• The supply voltage of the amplifi ers is 230 VAC which can be fatal if touched directly.
• The only reliable method of disconnecting the amplifi ers from the mains is to unplug them.
• Do not touch live parts.
• The power plug must be easy to operate as the means of cutting power to the amplifi er, so the wall outlet
must be close to the amplifi er and easily accessible.
• The amplifi ers may only be installed and deinstalled in the voltage-free condition.
• Do not operate the amplifi ers without the factory-fi tted protective cover over the power supply unit. The cover
must be closed.
• No liquid-fi lled items may be placed on top of the amplifi ers.
• The amplifi ers are not to be exposed to dripping or splashing water.
• Ambient temperature range -20 to +55°C
The amplifi ers comply with the EMC directive
2004/103/EC and Low-Voltage Directive 2006/95/EC
applicable at the time of shipping.
Test socket on output -20 dB (with directional coupler)
Test socket on input -20 dB
Test sockets are terminated with the EMK 03 in the
delivery status
Conform to: EN 60728-11, EN 50083-2 and EN 60065
For indoor installation
1 / 4
VOS
32/RA-1G 20910033
VOS
43/RA
20910030