Before Use
1.Remove all packaging from the kettle and its power base.
2.Before use for the first time, the kettle should be filled to the maximum mark and boiled.
3.the boiled water should be discarded and the kettle rinsed out with cold water. this procedure
should be carried out three times, to remove any manufacturing dust, etc.
poWer Base
1.the power base should be positioned as close to a power socket as possible and the mains lead
shortened to suit. excess mains lead can be stored in the cord storage area underneath the power
base and taken out at the exit location in the power base wall.
2.For the power base to stand level, the mains lead must be pushed fully into the exit location.
UsING YoUr Top keTTLe
Filling tHe Kettle
1. Open the lid and fill the kettle via the lid aperture, ensuring that the water level is below the MaX
mark. You will find this marking on the steam reflection plate of interior kettle.
2. do not overfill. if the kettle is overfilled, there is a risk that boiling water may be ejected.
sWitCHing On
1. the kettle couldn't be switched on until it locate on the power base (2) correctly.
2. Plug the power base into the power socket. if necessary, switch the socket on.
3. Fill the kettle with the amount of water required.
4. gently position the kettle on the power base, taking care not spill any water.
5. Press the bottom (3) of the "On/OFF switch" from "OFF" location to "On" location. the "Power
on light" will come on, to indicate that the kettle is now switched on. When the water has boiled,
the kettle will automatically switch off, the switch will return to the "OFF location" and the "Power
on light"will go out.
6. if you need to switch the kettle off before the water boils, please push the " On/OFF switch "
from "On location" to "OFF location".
important: ensure that the kettle has switched off automatically, or is switched off manually and
is disconnected, before moving it.
7. When filling or carrying the kettle, care should be taken to ensure it is not tilted backwards, as
this may allow water to pass on the control area, through the steam aperture, should this occur, the
kettle must be allowed to dry before use.
8. Pour slowly to avoid the risk of splashing.
OPeRatiOn WitH insuFFiCient WateR
1. if the kettle is switched on accidentally when it does contain sufficient water, a boil-dry device
will operate to cut off the current to the element.
2. the boil-dry device will switch the kettle off. You will not have to switch it off manually, then
unplug it from the mains. You must let it cool down fully before refilling, as the element will be hot,
and spitting may occur.
care aND MaINTeNaNce
sCale
1. scale is mainly calcium carbonate (chalk), a harmless, naturally occurring mineral found in most
water supplies. "Hard" water contains more of this mineral than "soft" water.
2. When water is heated, the minerals in the water solidify. this can make the water appear cloudy,
it may form a thin film on the surface of the water after boiling, it may look like whitish pieces of
plastic in the water, it may form a film on the walls or element of the kettle.
3. the tOP teC element fitted to your kettle has been designed and developed to resist the forma-
tion of harmful scale deposit on its surface.
4. On traditional kettle element, scale forms a hard white "crust" which adversely affects perfor-
mance and reduces the life of the element.
5. as soon as you notice a "film" forming on the water or on the walls or the element, simply rinse
the kettle and wipe it out.
6. to reduce the build-up of scale residues, always empty out any residual water after boiling. if
you stick to these simple rules, it should not be necessary to descale the kettle, even in a hard
water area.
7. any marking or residue on the element will not affect its performance or efficiency. if you do
decide that you want to descale the kettle, to remove any such residue, or to restore the appearance
of the kettle, you may do so, but please use a proprietary brand of descaler, suitable for use in
plastic-bodied products (even metal kettles have plastic parts).
All manuals and user guides at all-guides.com
Cleaning
1. unplug the power base from the power socket and let the kettle cool down completely before
cleaning.
2. Wipe the inside of the kettle with a damp cloth. the outside may be cleaned with a damp cloth,
and, if necessary, a little washing-liquid. do not let the washing-up liquid inside the body, as this
will taint the water, and always rinse the kettle thoroughly before use.
3. ensure that all connectors and sockets are kept dry.
4. do not immerse the kettle or power base in water or any liquid.
5. do not use harsh or abrasive cleaners.
coNNecTIoN To The MaINs sUppLY
1. Check that the voltage marked on the product corresponds with your supply voltage.
2. this product is fitted with a 13a plug complying with Bs1363. if this plug is unsuitable or needs
to be replaced, please note the following:
WaRning tHis aPPlianCe Must Be eaRtHed
important: the wires in the mains lead are coloured in accordance with the following code:
gReen/YellOW: eaRtH
Blue: neutRal
BROWn: liVe
specIfIcaTIoN
Volume: 1.7 liters
Power consumption: 2400 W
Power requirement: 220-240 V ~ 50/60 Hz
Hidden heating element
lid-operating button
Panel light
Power cord storage