2.16
Personal protective equipment
3
General description of the unit
3.1
Positioning
3.2
Electrical connection
equipment when it is connected to the power outlet, as the resulting vibrations and
movements could cause the condensate to escape from the special container affecting the
electrical parts.
The pump can be moved only after having emptied the condensate, and in any case it is
ALWAYS NECESSARY to remove the plug from the socket before moving it.
For the operations of use and maintenance of the units, use the following means of
personal protection:
Warning: It is strictly forbidden to remove the safety signs present in the units.
The pump is designed to take condensate water from the dehumidifier and discharge it to a
maximum height of 15 meters. The pump has a safety float inside which stops the dehumidifier in
case of pump malfunction.
Connect the pump to the dehumidifier using the 6 PIN connector provided.
ATTENTION: Connect the pump only after disconnecting the dehumidifier from the power
supply
Clothing: those who carry out maintenance or work with the unit must wear safety
shoes, with non-slip soles in environments with slippery floors.
Gloves: During cleaning and maintenance operations, the use of appropriate gloves is
required. When recharging the refrigerant gas, the use of appropriate gloves is
mandatory to avoid the risk of freezing.
Mask and goggles: during cleaning and maintenance, respiratory
protection masks and eye protection goggles must be used.
Place the pump in the dehumidifier, after removing the tank.
Connect the condensate drain of the dehumidifier with the supplied pipe,
female ¾ '' connection.
Make sure there are no kinks in the pipes.
Avoid double siphons in the pipes.
Attention: The image on the left is an example of installation.
The positioning varies according to the dehumidifier model.