SAFETY FEATURES

THERMAL RELIEF VALVE

A thermal relief valve is provided to protect the pump
from overheating if the spray gun is closed for an extended
length of time or the nozzle becomes plugged. However, it is
intended to be used as a backup system and every effort
should be made to not permit the pump to heat up.
We recommend turning the pressure washer off if it will
not be used for more than five minutes. This saves wear on
the unit, reduces fuel consumption and extends the life of the
pump by avoiding heat.

SAFETY LOCK OFF LATCH

To prevent accidental discharge of high pressure water,
the safety latch on the trigger should be engaged whenever the
pressure washer is not in use. (Refer to Operating
Instructions.)
LOW-OIL SHUTDOWN
The unit is equipped with a low oil sensor. If the engine
oil level becomes lower than required, the pressure washer
will automatically shut off. This protects your pressure
washer engine from operating without proper lubrication.
If the pressure washer engine shuts off and the oil level is
according to specification, check to see if the pressure washer
is setting at an angle that forces oil to shift. Place on an even
surface to correct this. If the engine fails to start, the oil level
may not be sufficient to deactivate low oil level switch. Be
sure the sump is completely full of oil.
The pump will overheat and may be damaged, or cause
damage if allowed to circulate more that five minutes.

SPARK ARRESTING MUFFLER

YOUR PRODUCT MAY NOT BE EQUIPPED WITH A SPARK
ARRESTING MUFFLER. If the product will be used around
flammable materials, such as agricultural crops, forests, brush, grass,
or other similar items, then an approved spark arrester should be
installed and is legally required in the State of California.
California statutes requiring a spark arrester are Sections 13005(b),
4442 and 4443. Spark Arresters are also required on some U.S. Forest
Service land and may also be legally required under other statutes and
ordinances.
An approved spark arrester is available from your
Coleman® Powermate® product dealer, or may be ordered from
Powermate Corporation, P.O. Box 6001, Kearney, Nebraska 68848.
1-800-445-1805.

SPECIFICATIONS

Maximum Inlet Pressure . . . . . . . . . . . . . . . . . .Up to 90 PSIG
RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3600 RPM
Temperature of Pumped Fluids . . . . . . . . . . . . . . . .Up to 80°F
Inlet Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8" BSP
Discharge Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8" BSP
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 lbs.
www.powermate.com
Crankcase oil Capacity . . . . . . . . . . . . . . . . . . . . . . . .4.7 fl. oz.
Pump oil . . . . . . . . . . . . . . . . . . . . . . .SAE 30W Nondetergent
Consult the factory for special requirements that must be met
if the pump is to operate beyond one or more of the limits
specified above.

HIGH PRESSURE/LOW PRESSURE

The high pressure nozzle position is intended for cleaning.
When high pressure is required, grasp collar and slide the
collar and nozzle toward the gun.
NOTE: Make sure the nozzle cover is pulled to the
extreme rear position to lock the nozzle in the high
pressure position.
High Pressure
Low Pressure
When low pressure is required, grasp and slide the nozzle
cover away from the gun.

ADJUSTABLE SPRAY NOZZLE

The adjustable spray nozzle can adjust spray from fan to
pencil point in both the high and low pressure positions. The
spray is adjusted by turning the nozzle cover.
FanSpray
The
To increase angle to a fan spray,
turn counterclockwise.
Pin Point Spray
To decrease angle to a pencil point
spray, turn clockwise.
CAUTION: The pencil point spray adjustment
is very aggressive. We recommend that for most
cleaning applications, a twenty degree (20°)
spray angle be used to avoid damage to the
surface being sprayed.