1.3.2 Wall mounted device
1.3.2.1 Preparation
- The wall mounted installation concern all Mechanical devices and
Electronic devices.
a. Release the appliance's hook-on bracket (Figure ²)
Have a straight head screwdriver to hand and lift the tab taking care
not deform. While holding the tab rose, push the locking bracket
to the bottom of the unit to release the upper hooks. Rotate the
attachment tab around the lower hooks and remove the attachment
tab.
- Place the bracket on the ground and against the wall and mark the
drilling points A. These give the position of the bottom fasteners.
Replace the brackets in alignment with the drilling point A to locate
drilling points B. These give the position of the upper fasteners. In
case of special support, use proper anchors. Position and screw the
wall brackets.
- The appliance should have a 230 / 50Hz power supply. The panel
heater must be connected to the mains by a 2-wire cable for
Mechanical Device or 3-wire cable for Electronic Device (Brown=
Phase, Blue = Neutral, Black = Pilot wire) by means of a connexion
box. In humid areas such as bathrooms and kitchens the power
break of at least 3 mm.
- Connection to earth is prohibited / Do not connect the pilot wire
(black) to earth. If a driver or driven device is protected by a 30mA
differential (for example for bathroom) it is necessary to protect the
power supply of the pilot wire on that differential.
Commands
No current
Received
Oscilloscope
Ref/Neutral
Mode
COMFORT
obtained
(Figure ¶)
Complete
Negative
altermation
Half/altermation
230 V
– 115V
ECO
ANTI - FREEZE
Positive
Half/altermation
+ 115V
STOP HEATING
LOAD SHEDDING
11