• on firm ground away from flooding and out of reach of animals and children
• inside a protective fence, if required.
The solar panel should face true south.
Mounting the energiser
Mount the energiser directly onto a T­post or earth stake. To mount onto
a wooden post use the hardware provided (see sketch to the right).
The solar panel should face true south.
Connecting to an electric fence
Push an 1 m earth stake fully into firm ground.
Connect the green lead from the fence earth terminal on the energiser to the earthing system.
Connect the red lead from the fence output terminal on the energiser to the fence. Make sure
there is a good contact.
Caution! Make sure the connecting leads drop downwards from the energiser to prevent water
from collecting at the terminal.
P35
Operation (P35 only)
Switching on and off
1. To switch on, switch the On/Off switch
P50
2. To switch off, switch the On/Off switch
Pulse indicator light
The pulse indicator light displays the pulse speed. The pulse
speed varies according to the battery charge level.
Battery charge level
High
Normal
Low
to I.
to 0.
Typical pulse speed
A pulse every second
A pulse every 1.5 seconds
A pulse every 3 seconds
- 37 -