Télécharger Imprimer la page

Viesta VAC-09CH Manuel D'installation Et D'utilisation page 22

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL - INSTALLATION OF THE INDOOR UNIT
Before starting installation, decide on the position of the indoor
and outdoor units, taking into account the minimum space reser-
ved around the units
● Do not install your air conditioner in a wet room
such as a bathroom or laundry etc
● The installation site should be 250cm or more
above the floor.
TO INSTALL, PROCEED AS FOLLOWS
INSTALLATION OF THE MOUNTING PLATE
1. Always mount the rear panel horizontally and vertically
2. Drill 32 mm deep holes in the wall to fix the plate
3. Insert the plastic anchors into the hole;
4. Fix the rear panel on the wall with provided tapping screws
5. Be sure that the rear panel has been fixed firmly enough to
withstand the weight
Note: The shape of the mounting plate may be different from
the one above, but installation method is similar.
DRILLING A HOLE IN THE WALL FOR THE PIPING
1. Make the piping hole (Ø 65) in the wall at a slight downward
slant to the outdoor side.
2. Insert the piping-hole sleeve into the hole to prevent the
connection piping and wiring from being damaged when
passing through the hole.
● The hole must slope downwards towards the exterior
Note: Keep the drain pipe down towards the direction of the
wall hole, otherwise leakage may occur.
ELECTRICAL CONNECTIONS - INDOOR UNIT
1. Open the front panel.
2. Take off the cover as indicated in the piciure (by removing a
screw or breaking the hooks).
3. For the electrical connections, see the circuit diagram on the
right part of the unit under the front panel.
4. Connect the cable wires to the screw terminals by following
the numbering. Use wire size suitable to the electric power
input (see name plate on the unit) and according to all current
national safety code requirements.
● Use wire size suitable to the electric power input (see name plate on the unit) and according to all
current national safety code requirements.
● The cable connecting the outdoor and indoor units must be suitable for outdoor use.
● The plug must be accessible also after the appliance has been installed so that it can be pulled out
if necessary.
● An efficient earth connection must be ensured.
● If the power cable is damaged, it must be replaced by an authorised Service Centre.
Note: Optional the wires can been connected to the main PCB of indoor unit by manufacturer according to the
model without terminal block.
EN
22
KEN002VAC
v1• 11.11.2020
outdoors
indoors
5mm
front panel
wiring diagram
terminal block cover

Publicité

loading

Produits Connexes pour Viesta VAC-09CH

Ce manuel est également adapté pour:

Vac-12chVac-18chVac-24ch