2. General information
Earthing
If earthing points exist in/on the frame and devices, these must be connec-
ted to the earthing.
Earthing symbol
Ludwig-Rinn-Straße 10-14 • D- 35452 Heuchelheim/Gießen • Phone: +49 6 41-9 62 84-0 • Fax: +49 6 41-9 62 84-28 • www.tci.de
4 / 9
Recessed housing
Flush-mounted recessed installation.
Top design.
Type of installation requiring the most work,
as it must be mounted on the installation
box as well.
The ambient air is used for cooling.
3. Preparing for installation
The recessed housing can be installed in both solid and cavity walls.
Recommended positioning of the recessed housing:
The correct installation height for the recessed housing depends on how tall the user is.
We recommend positioning the housing so that the centre of the display is approximately
1650 mm above the floor.
Removal from the recessed housing:
Loosen the 4 screws on the sides and remove
the device from the recessed housing.
Installing the recessed housing
When using recessed housing, note that the top edge finishes with the surface of the wall.
The box is screwed in from the inside.
Therefore, it is possible to adjust the recessed housing after installation in the wall. As the
front edge of the recessed housing remains visible, it must be protected when the wall
undergoes final processing.
The device must only be installed by authorised specialists and electricians.
!
tci GmbH does not accept any liability for the mounted housing and its func-
tion. Inspection by a specialist is required.
Only carry out installation work when power supply lines are disconnected.