Télécharger Imprimer la page

golmar M ART 7W/G2+ Guide Rapide page 4

Masquer les pouces Voir aussi pour M ART 7W/G2+:

Publicité

Les langues disponibles

Les langues disponibles

ART 7W/G2+ MONITOR
SAFETY PRECAUTIONS
Always disconnect the power supply
-
before installing or making modifications to the device
.
- The fitting and handling of these devices must be carried out by authorised personnel
.
- The wiring must run at least 40 cm. away from any other wiring
- Do not overtighten the screws on the connector
- Install the monitor in a dry protected location free from the risk of dripping or splashing water
- Do not place in humid, dusty or smoky locations, or near sources of heat
- Before connecting the device to the mains, check the connections between the door panel, power
supply, distributors and monitors
-
Always follow the instructions contained in this manual
( )
CHARACTERISTICS
*
-
Hands-free monitor.
- 7" colour screen.
- Touch screen for access and selection of menu function.
- Monitor with Wifi transmission for call forwarding to a smartphone.
- Monitor with simple installation (non-polarised 2 wires bus).
- User menu.
- Installer menu.
- Image and communication settings menu.
- Output auxiliary call repeater (max. 50mA/12V).
- "HZ" input for calls from apartment front door.
- Hidden Push buttons for Start/Stop Commnunication & Door Opening.
- Notification leds.
- Configuration switches to assign the call address (1 to 128) and end of line.
( )
SYSTEM OPERATION
*
-
To make a call, the visitor must press the button of the apartment; an audible sound indicates that the
call is being made and LED
will turn on. If vocal synthesis is enabled, a 'Call is in progress' message
appears indicating that a call is being made. At this moment, the apartment's monitors receive the call.
If another apartment is called by mistake, press the button for the correct apartment and the first call
will be cancelled.
- Upon receiving the call, the image will appear on the screen of the master monitor (and slave 1, if it
exists) without the visitor knowing and icon
image from slave monitors 2 or 3, press the screen for the image to appear. If the call is not answered
within 45 seconds, LED
will turn off and the system will become free.
- To establish communication, press off-the-hook icon
and the led
will
turn on
.
- Connection will last for 90 seconds or until on-the-hook icon
communication ends, LED
will turn off and the system will become free. If vocal synthesis is enabled,
a 'Communication is finished' message will indicate that the call is over.
-
To open door
ó
of the door panel
, press the corresponding icon
1
2
communication processes: one press will activate the lock release for seconds and LED
turn on for seconds. If vocal synthesis is enabled, a 'Door
3
door panel.
-
Detailed operation
and configuration
of the monitor
INSTALA
TION OF THE
MONITOR
( )
*
( ) For more information, see
*
"TART 7W/G2+"
https://doc.golmar.es/search/manual/50122463
displayed on the screen will blink green. To view the
on the screen. Door panel LED
will turn off
is pressed
on the screen
. When
on the screen
during the call or
3
will also
is
open' message will be indicated on the
, see "TART W/G2+" user manual
7
.
user manual
(cód. 50122463)
2
ART 7W/G2+ MONITOR
( )
DESCRIP
TION
MONITOR
*
A
B
C
D
I
J
K
I
( )
Monitor address (code) setup: (Note: Monitor with V.07 or later version).
*
Dip1 Dip7:
-
Sets the monitor address (addresses to
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
monitor code is the sum of the values of the switches set to ON
Important: Apartment 1 (Dip1 to ON & Dip2-Dip to OFF).
Important: Apartment 2 (Dip1 - Dip to OFF).
1 8
Dip1 Dip7:
-
These assign the address of the monitor to call button on the door panel.
Apartment 1
1 ( )
ON
1
2
3
4
5
6
7
8
1 ( )
Apartment 1 (Dip 1 to ON) ART 7W/G2+ Monitor with V04 and later.
Dip8: This activates the end-of-line resistance in the ON position. Activate it on monitors where the bus cable ends.
Deactivate it only in intermiadate monitors.
Not : e
If there are more than
s
lave or slave (by function code). The WiFi Monitor must be always the Master.
2
3
( )
*
For more information, see
https://doc.golmar.es/search/manual/50122463
EN
A.
Speaker
B.
Notification icons:
Power on indicator
Do not disturb
Auxiliary relay activated
Door opening
E
New image/video
Wi-Fi transfer activated
C.
Hidden start/stop communication button
F
Note: ART 7W/G2+ monitor 'V.01 + No. 6539 and
V.02' or later: For the visually impaired, by default
G
deactivated (see "TART 7W G2+" manual, code
H
50122463)
D.
Raised dots for the visually impaired
E.
Touch screen
F.
Hidden door opening button
Note: ART 7W/G2+ monitor 'V.01 + No. 6539 and
V.02' or later: For the visually impaired, by default
I
deactivated (see "TART 7W G2+" manual, code
50122463)
ON
UID: mnvx8d8uskpv
G.
MicroSD card slot
1
2
3
4
5
6
7
8
L
SA
BUS
GND
BUS
Type: MicroSD Class 10 from 4Gb to 128 Gb
HZ
24V
K
HZ
GND
H.
Microphone
I.
I
Wall mounting connector fixing (x4)
J.
Configuration switches
K.
Installation terminals
L.
UID code label of the monitor
Building / Villa (Nexa Door Panel)
1
1 8
2
).
7
Table of values
Switch number:
1 2 3 4 5 6 7
7
Value when ON
:1 2 4 8 16 32 64
Chalet (SOUL
Door Panel
)
*
Apartment 2
Apartment 3
Apartment 4
ON
ON
ON
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
Dip 8
to
ON
Dip 8
ON
ON
1
2
3
4
5
6
7
8
1
2
1 monitor
in the apartment see
,
"TART 7W
/G2+ manual to define the monitor as lave
"
"TART 7W/G2+"
user manual
(cód. 50122463)
3
/
/
(not included)
ON
1
2
3
4
5
6
7
8
Example: 0+0+4+0+16+0+0 = 20
*
Manual
3
4
5
6
7
8
Kit Soul / Art 7W
to
OFF
3
4
5
6
7
8
s
1,
EN

Publicité