RT608 Engine temperature alarm SEYMO
English
2º engine configuration
For each engine / exhaust you have to adjust two
temperatures, follow the steps below.
Once setup is complete try lower engine / exhaust
temperature that works perfectly.
Push button up 2 configuration. Press for 3 seconds to
change the maximum temperature at which the motor
alarm will be activated. With the plus and minus buttons,
+
-
when it is at the desired value, wait 3 seconds, and the
alarm value will be saved.
2º Engine
Button down 2 configuration. Press for 3 seconds to set 1
degree less than the previous maximum temperature. When
it is at the desired value, wait 3 seconds, the alarm value will
be saved.
+
-
Example maximum temperature = 85 degrees (button up 2)
Down button2 = 84 degrees
To see the programmed temperatures, momentarily press each
engine 1º
and
engine 2º button.