GAS COMPONENT CONNECTION CHECKS
3. Make sure that the ignitor pin and thermocouple are correctly positioned.
- The ignitor pin should be pointed straight to the thermocouple.
- The thermocouple should be positioned 5mm away from the burner tube.
Thermocouple
Wire
4. Make sure that the thermocouple wire is correctly positioned. The thermocouple
wire should be in line with the valve.
Thermocouple
Valve
Igniter Box
5mm
Thermocouple Wire
17
Ignitor Pin
Wire should
be in line
with valve