POMPE DE SPA
7. START-UP
▪ Start electrically the pump only when the suction and discharge pipes are connected to the corresponding inlets and
outlets.
▪ Apply voltage to the motor and suitably adjust the jets to obtain the desired flow.
8. MAINTENANCE AND CLEANING
▪ Our pumps for hydro massage facilities do not require any special maintenance or programming.
▪ If the pump will be idle for a long period of time, it is recommended to disassemble, clean and store it in a dry, well
ventilated place.
▪ If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person
to a hazard.
9. TROUBLESHOOTING GUIDE
Symptom
Pump does not turn
Pump not properly pumping
15 Rue des Marais 44310 ST Philbert de Gd Lieu – Tel. 02 40 59 95 35 – www.acis-france.com
SPA PUMP
Possible causes
-Incoming power to the pump?
-Is circuit breaker on?
-Is GFCI operating properly?
No power to pump
-Is the air switch plugged in?
-Is the air switch hose connected to the
pump?
-Is the air switch hose connected to the
Air switch disconnected
actuator button on the tub deck?
-Jets should be pointed away from the
suction inlet so air is not forced into
pump suction.
-Is the in tub suction inlet blocked
Blockage or leak
or covered?
-Is there any debris in the pump
housing?
-Is there a leak in the piping or the
pump?
-Is the proper voltage applied to the
pump?
-Is there an extension cord being used?
Low voltage