S8-PR/MR...W13
Contrast sensor
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (yellow)
The yellow LED ON indicates the output status.
READY LED (green)
The green LED ON indicates the powering status.
SET PUSH-BUTTON
A long pressure on the push-button activates the teach procedure.
The REMOTE input allows the external control of the SET push-button.
DARK/LIGHT TRIMMER (only for dynamic setting)
The light/dark mode is selected by a monoturn trimmer.
Please refer to the "SETTING" paragraph to get the correct setting procedure.
WARNING: the maximum mechanical rotation range of the trimmer is 240°.
Do not force over of the maximum and minimum positions.
INSTALLATION
S8-PR:
The sensor can be positioned by means of the two housing
holes using two screws (M3x18 or longer, 0.8Nm maximum
tightening torque) with washers.
S8-MR:
The sensor can be positioned by means of the
two threaded holesusing two screws (M3x14 or
longer, 0.8Nm maximum tightening torque) with
washers.
Various orientable fixing brackets to ease the
sensor positioning are available (please refer
to the accessories listed in the general
S8-PR
catalogue).
The operating distance is measured from the front surface of the sensor
optics.
Mark detection on a reflective surface is improved
adjusting the beam direction to 5° ... 20° from
surface axis.
CONNECTIONS
M8 connector
Pig-tail with M12 connector
Power supply:
Ripple:
Current consumption
(output current excluded):
Outputs:
Output current:
Output saturation voltage:
Response time:
Switching frequency:
Emission type:
Spot dimension:
Operating distance (typical values):
Depth of field:
LIGHT/DARK selection:
Indicators:
Operating temperature:
Storage temperature:
Dielectric strength:
Insulating resistance:
Ambient light rejection:
Vibrations:
Shock resistance:
Housing material:
Lens material:
Mechanical protection:
Connections:
Weight:
AtEx 2014/34/EU:
SETTINGS
MARK-BACKGROUND ACQUISITION
Mark acquisition
The DARK/LIGHT mode is automatically
selected by the sensor.
Place mark in front of the sensor spot and
press SET push-button until the green READY
LED turns off (1 sec).
The sensor functions alternating red, green and
blue emissions.
Do not move the mark during this phase.
S8-MR
Background acquisition
Place background in front of the sensor spot
and press SET push-button again.
The sensor functions alternating red, green and
blue emissions.
Do not move the mark during this phase.
DYNAMIC ACQUISITION
Use the dynamic setting to detect moving
target. The sensor sets automatically the
threshold value during target movement. The DARK/LIGHT mode has to
be previously set.
LIGHT/DARK MODE SETTING
LIGHT mode setting
Rotate trimmer in an anti-clockwise direction to set the
LIGHT mode (clear mark on dark background).
DARK mode setting
Rotate trimmer in a clockwise direction to set the DARK
mode mode (dark mark on clear background).
Dynamic detection
Position the sensor spot in front of the target to detect.
Press SET push-button until the green READY LED turns off (3sec) and keep it pressed.
To end the dynamic detection procedure release the SET push-button.
The sensor functions alternating red, green and blue emissions.
SETTING RESULT
The switching threshold is typically placed 25% below the mark. If the sensing conditions are accepted, at the end of teach procedure the READY LED
blinks x2 for 3sec. If SET push-button is pressed in this 3 seconds the switching threshold is placed in the midpoint between the mark and the background.
If the READY LED blinks fast the acquisition failed for to insufficient contrast.Press SET push-button and the sensor returns to the previous setting
TECHNICAL DATA
S8-PR...W13
12 ... 30 VDC Class 2 (Type 1 for S8-MR) UL508
2 Vpp max.
30 mA max
PNP or NPN N.O.; 30 VDC max. (short-circuit protection)
Pull-down/up resistance = 47 K
100 mA (overload protection)
2 V
20 s
25 kHz
BLUE ( 465 nm) / GREEN (520 nm) / RED (630 nm) with automatic selection
2
3x1 mm
9 mm
3 mm
Mono-turn trimmer (only for dynamic setting)
OUTPUT LED (YELLOW) / READY LED (GREEN)
-10 ... 55 °C
-20 ... 70 °C
: 1500 VAC 1 min. between electronics and housing
>20 M 500 Vdc between electronics and housing
according to EN 60947-5-2
0.5 mm amplitude, 10 ... 55 Hz frequency, for each axis (EN60068-2-6)
11 ms (30 G) 6 shocks for each axis (EN60068-2-27)
ABS (S8-PR) / INOX AISI 316L (S8-MR)
Window in glass; lens in PC (S8-PR) / window in PMMA (S8-MR)
IP67 (S8-PR) / IP67, IP69K (S8-MR)
M8 4-pole connector / 150 mm 4 mm cable with M12 4-pole connector (S8-PR pig-tail vers.)
12 g. max. (S8-PR connector vers.) / 50 g. max.pig-tail (S8-PR pig-tail vers.)
70 g. max (S8-MR connector vers.)
II 3G EX nA II T6 ;
II 3D EX tD A22 IP67 T85°C
OTHER FUNCTIONS
KEYLOCK function (keyboard lock)
The KEYLOCK function (keyboard lock) allows to deactivate the SET
push-button avoiding accidental changes in the sensor setting.
If at sensor powering the REMOTE wire is connected to +Vdc for at least 1
sec., the keylock function is activated and the push-button is no longer
active.
To deactivate the keylock, the sensor must be turned off and repowered
with the REMOTE wire not connected or connected to GND.
REMOTE input
Different detection functions can be made with the REMOTE signal,
without using the SET push-button.
The REMOTE wire connected to +VDC is equal to pressing the SET push-
button, it connected to GND or not connected is equal to not pressing the
SET push-button.
The connection duration of the REMOTE wire to +VDC determines the
detected type requested:
VDC
REMOTE
1s
GND
LIGHT
Mark acquisition
VDC
DARK
REMOTE
3s
GND
Start
Dynamic acquisition
S8-MR...W13
sensors are NOT safety devices, and so MUST NOT be used in the safety control of the
Background acquisition
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
End
Dynamic acquisition
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions, Support.
The warranty period for this product is 36 months. See General Terms and Conditions of Sales for
further details.
Under current Italian and European laws, Datalogic is not obliged to take care of product
disposal at the end of its life. Datalogic recommends disposing of the product in compliance with
local laws or contacting authorised waste collection centres.
© 2013 - 2017 Datalogic S.p.A. and/or its affiliates ALL RIGHTS RESERVED. Without limiting the
rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a
retrieval system, or transmitted in any form or by any means, or for any purpose, without the express
written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are registered
trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks
and brands are property of their respective owners. Datalogic reserves the right to make modifications
and improvements without prior notification.
DIMENSIONS
15
machines where installed.
821002673 Rev. C