T
1. Introduction ............................................................................................... 3
2. Safety regulations ..................................................................................... 4
3. Shipping & Packing ................................................................................... 6
4. System Overview ....................................................................................... 7
5. Installation & Operating instructions ....................................................... 8
6. Resin Change ........................................................................................... 10
7. Technical data ......................................................................................... 11
Contents under pressure can cause severe injury
or death from tank rupture.
When starting system:
• Check system for cracks.
• Be sure cover is in locked position.
• Do not exceed pressure of 8 Bar (116 psi).
• Keep discharge line open and hold yellow lever
down to remove trapped air from system.
• For use only with drinking water
Before servicing system:
• Shut off drinking water supply and open waterfed
pole tubing discharge line.
• Disconnect water supply and allow tank to drain.
• Prior to opening vessel housings, turn off water
and relief pressure in hose. Press yellow opening
lever to get pressure out of the housings.
STORAGE: Do not store resin in open or unlabelled containers. Store in a cool, dry place
(5°C to 40°C).
DISPOSAL: Dispose of in accordance with applicable federal, state/provincial, and local
regulations. All HydroPower
(commonly referred to as de-ionizing resin). This resin will require replacement and handling.
2
HydroPower® Ultra
Table of contents
DANGER
!
Ultra units require the use of mixed bed ion exchange resin
®
www.ungerglobal.com
• Spilled resin is a slipping hazard.
Clean up spilled resin immediately.
• Resin can cause skin irritation.
Avoid skin contact.
• Wash hands thoroughly after use.
• Can cause eye irritation. Avoid eye contact.
Wear safety goggles. In case of eye contact,
immediately flush eyes thoroughly with
clean water. Consult doctor if symptoms
persist.
• Do not drink the water produced by this
system. This water is too pure and will rob
the body of vital minerals.
READ MANUAL BEFORE USING PRODUCT!