SmartVFD HVAC2
GENERAL
SmartVFD HVAC2 variable frequency drives provide step
less speed control for various applications:
• Pumps
• Fans
• Compressors
FEATURES
• Compact size - saves space in your equipment
cabinet
Models available up to 25HP
• Permanent Magnet motor support
• Energy optimization feature
• Programmable FB (Fieldbus) process data
• Settable Limit supervisions
• Temperature measurement with temperature sensor
option board HVFDOPTTMP
• Flexible side-by-side mounting with screws or DIN-
rail as standard for MI1-MI3 frame sizes
• Single rating suitable for both pump and fan or
machine applications
• Maximum ambient temperature: + 122 °F for most
drives
• Fire Mode feature
• Integrated RFI-filters
• Models available with or without Class C2 EMC filter
• Wide input and output connection possibilities
• Configurable inputs and outputs
• 30 second Start-Up Wizard
• Easy "keypad to remote" change with 1 button
• Parameter upload/download even without main
power to the drive with HVFDCABLE accessory
• Quiet motor operation with 4 kHz switching
frequency
• Overtemperature ride-through
• Motor pre-heat
• Power ride-through
• Automatic restart
• Integrated PID controller
• Optional NEMA 1 enclosure
• Built in RS485 Modbus communication
SPECIFICATIONS
Mains Connection
Input voltage U
in:
115 V, -15%...+10% 1~
208...240 V, -15%...+10% 1~
208...240 V, -15%...+10% 3~
380 - 480 V, -15%...+10% 3~
600 V, -15%...+10% 3~
Input frequency: 45...66 Hz
Connection to mains: Once per minute or less (normal
case)
Supply Network
Networks:
SmartVFD HVAC2 (400 V) cannot be used with corner
grounded networks
Short circuit current:
Maximum short circuit current has to be < 50 kA
PRODUCT DATA
31-00109EF-01

Publicité

Table des Matières
loading

Sommaire des Matières pour Honeywell SmartVFD HVAC2

  • Page 1 HVFDOPTTMP Networks: • Flexible side-by-side mounting with screws or DIN- SmartVFD HVAC2 (400 V) cannot be used with corner rail as standard for MI1-MI3 frame sizes grounded networks • Single rating suitable for both pump and fan or...
  • Page 2 SMARTVFD HVAC2 Motor Connection Altitude: 100% load capacity (no derating) up to 3281 ft. (1000 m). Output voltage: 0 - U 1% derating for each 328 ft. (100 m) above 3281 ft. Output current: (1000 m); max. 6562 ft. (2000 m) Continuous rated current I at ambient temperature max.
  • Page 3 SMARTVFD HVAC2 MODELS Mains voltage 208-240 V Table 1. Mains voltage 208-240 V, 50/60 Hz, 1~ series. Nominal Motor shaft input Rated loadability power current 100% contin. 150% overload Mechanical Weight Part number current I current [A] [HP] [KW] size (lbs) HVFD2D1B0003E2 1.7...
  • Page 4 SMARTVFD HVAC2 Mains voltage 115 V Table 3. Mains voltage 115 V, 50/60 Hz, 1~ series. Motor shaft Nominal input Rated loadability power current 100% contin. 150% overload Mechanical Weight Part number current I current [A] [HP] [KW] size (lbs) HVFD2D1A0003 0.33...
  • Page 5 B = 208 V - 240 V C = 380 V - 480 V F = 520 V - 600 V Phases 1 = Single Phase 3 = 3-Phase Product Family HVFD2D = Honeywell SmartVFD HVAC2 MCR36499A Fig. 1. SmartVFD HVAC2 type designation code. 31-00109EF—01...
  • Page 6 SMARTVFD HVAC2 MECHANICAL MOUNTING There are two possible ways to mount SmartVFD HVAC2 in the wall. For MI1-MI3, either screw or DIN-rail mounting; For MI4-MI5, screw or flange mounting. BACK RESET M36503 Fig. 5. Flange mounting, MI4 - MI5 BACK...
  • Page 7: Table Des Matières

    Dimensions in inches (mm) .7 (17) .9 (22.3) 1.7 (44) 4 (102) (H1) Fig. 11. SmartVFD HVAC2 dimensions, MI2 - 3 Display Location. L2 L3 DC+R+ R- DC- U/T1 V/T2 W/T3 W (W1) D (D1) M36509 Fig. 10. SmartVFD HVAC2 dimensions, MI4 - MI5.
  • Page 8: Mi1

    SMARTVFD HVAC2 COOLING Enough free space shall be left above and below the frequency converter to ensure sufficient air circulation and cooling. You will find the required dimensions for free space in the table below. If several units are mounted above each other the required free space equals C + D. Moreover, the outlet air used for cooling by the lower unit must be directed away from the air intake of the upper unit.
  • Page 9: Mi2

    16-12 16-12 20-16 20-16 1.5HP 2*10+10 3*16+16 16-12 16-12 20-16 20-16 Table 12. Cable and fuse sizes for SmartVFD HVAC2, 208 - 240 V, 1~. Terminal cable size (min/max) Main Earth Control Relay Fuse Mains cable Motor cable terminal terminal...
  • Page 10: Mi4

    SMARTVFD HVAC2 Table 13. Cable and fuse sizes for SmartVFD HVAC2, 208 - 240 V, 3~. Terminal cable size (min/max) Main Earth Control Relay Fuse Mains cable Motor cable terminal terminal terminal terminal Frame Horsepower Cu [AWG] Cu [AWG] [AWG]...
  • Page 11 RESISTOR RESISTOR MOTOR (NOT USED) MAINS M36557 (NOT USED) M36556 Fig. 17. SmartVFD HVAC2 power connections, MI5. Fig. 16. SmartVFD HVAC2 power connections, MI4. Control cabling ATTACH THE SUPPORT AFTER INSTALLING ATTACH THE SUPPORT AFTER INSTALLING ATTACH THIS PLATE THE POWER CABLES...
  • Page 12 SMARTVFD HVAC2 CONTROL CABLE TIGHTENING TORQUE: 0.4 NM STRIP THE PLASTIC CABLE COATING FOR 360° EARTHING M36560 M36562 Fig. 20. Open the lid, MI1 - MI3. Fig. 22. Install the control cables. MI1 - MI3. M36561 Fig. 21. Open the lid, MI4 - MI5.
  • Page 13 SMARTVFD HVAC2 The table below shows the SmartVFD HVAC2 control connections with the terminal numbers. Table 16. SmartVFD HVAC2 General purpose application default I / O configuration and connections for control board P = Programmable function. 1–10 kΩ Terminal Signal...
  • Page 14 High maximum ambient operating temperature Uninterruptible operation + 122 °F (some exceptions) Side by side mounting with SmartVFD HVAC2 MI1-MI3 can be mounted side by side with Easy installation screws or DIN-rail as no space between the units either with screws or on DIN-rail...
  • Page 15 HVFDCDNEMA1FR3/U Nema 1 Kit MI3 HVFDCDNEMA1FR4 Nema 1 Kit MI4 HVFDCDNEMA1FR5 Nema 1 Kit MI5 HVFD2DMOUNTKIT/U SmartVFD HVAC2 door mounting kit HVFDCABLE/U SmartVFD Commissioning Cable and USB Adapter HVFDCDMCA/U Compact Commissioning Device HVFDCDMCAKIT/U Compact Commissioning Kit (Cable, USB Adapter, and Device combined) Table 22.
  • Page 16 SMARTVFD HVAC2 By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys’...
  • Page 17 • Montage côte à côte flexible avec vis ou rails DIN Réseaux : standard pour les dimensions de cadre MI1-MI3 Le SmartVFD HVAC2 (400 V) ne peut pas être utilisé avec des réseaux à une phase connectée à la terre • Régime nominal unique adapté aux applications de...
  • Page 18 SMARTVFD HVAC2 Raccordement du moteur Particules mécaniques : IEC 721-3-3, unité en service, classe 3S2 Tension de sortie : 0 - U Altitude : Courant de sortie : Capacité de charge de 100 % (sans réduction de charge) Courant nominal continu IN à une température ambiante jusqu'à...
  • Page 19 SMARTVFD HVAC2 MODÈLES Tension secteur 208-240 V Tableau 1. Tension secteur 208-240 V, 50/60 Hz, série monophasée. Puissance de Courant l'arbre du d'entrée Capacité de charge nominale moteur nominal Courant de Courant continu à surintensité à Dimensions Numéro de pièce...
  • Page 20 SMARTVFD HVAC2 Tension secteur 115 V Tableau 3. Tension secteur 115 V, 50/60 Hz, série monophasée. Puissance de Courant d'entrée Capacité de charge nominale l'arbre du moteur nominal Courant de Courant continu surintensité à Dimensions Poids Numéro de pièce à 100 % I...
  • Page 21 C = 380 V - 480 V F = 520 V - 600 V Phases 1 = monophasé 3 = triphasé Gamme de produits HVFD2D = Honeywell SmartVFD HVAC2 MFCR36499 Fig. 1. Code de désignation du type SmartVFD HVAC2. 31-00109EF—01...
  • Page 22 SMARTVFD HVAC2 MONTAGE MÉCANIQUE Il existe deux possibilités d'installation du SmartVFD HVAC2 au mur. Pour MI1-MI3, montage à vis ou sur rail DIN; pour MI4-MI5, montage à vis ou sur bride. BACK RESET M36503 Fig. 5. Montage sur bride, MI4 - MI5...
  • Page 23 SMARTVFD HVAC2 DIMENSIONS H (H1) BACK RESET D (D1) W (W1) M36508 Fig. 9. Dimensions du SmartVFD HVAC2, MI1 - MI3. M36510 Châssis Dimensions en pouces (mm) .7 (17) .9 (22.3) 1.7 (44) 4 (102) (H1) Fig. 11. Dimensions du SmartVFD HVAC2, MI2 - 3 Emplacement de l'affichage.
  • Page 24 SMARTVFD HVAC2 REFROIDISSEMENT Il convient de laisser suffisamment d'espace libre au-dessus et en dessous du variateur de fréquence pour garantir une circulation de l'air et un refroidissement suffisants. Vous trouverez les dimensions requises pour l'espace libre dans le tableau ci-dessous.
  • Page 25 1,5 HP 2*10+10 3*16+16 16-12 16-12 20-16 20-16 Tableau 12. Tailles de câbles et de fusibles pour le SmartVFD HVAC2, 208 - 240 V, monophasé. Taille du câble de la borne (min./max.) Câbles Câble de Borne Borne de Borne Fusible...
  • Page 26 SMARTVFD HVAC2 Tableau 13. Tailles de câbles et de fusibles pour le SmartVFD HVAC2, 208 - 240 V, triphasé. Taille du câble de la borne (min./max.) Câbles Câble de Borne Borne de Borne Fusible secteur Cu moteur Cu principale Borne de...
  • Page 27 SMARTVFD HVAC2 Triphasé (380 V, 480 V) Triphasé (380 V, 480 V) SORTIE MOTEUR SORTIE MOTEUR SECTEUR MOTEUR RÉSISTANCE RÉSISTANCE DE FREINAGE DE FREINAGE MOTEUR (NON UTILISÉE) SECTEUR MF36557 (NON UTILISÉE) MF36556 Fig. 17. Raccordements électriques du SmartVFD Fig. 16. Raccordements électriques du SmartVFD HVAC2, MI5.
  • Page 28 SMARTVFD HVAC2 COUPLE DE SERRAGE DU CÂBLE DE COMMANDE : 0,4 NM ENLEVEZ LE REVÊTEMENT EN PLASTIQUE DU CÂBLE POUR UNE MISE À LA MASSE M36560 À 360° MF36562 Fig. 20. Ouverture du couvercle, MI1 - MI3. Fig. 22. Installation des câbles de commande. MI1 - MI3.
  • Page 29 SMARTVFD HVAC2 Le tableau ci-dessous indique les raccordements de commande du SmartVFD HVAC2 avec les numéros de bornes. Tableau 16. Configuration et raccordements par défaut des E/S pour la carte de commande avec l'application généraliste du SmartVFD HVAC2 P = Fonction programmable.
  • Page 30 + 122 °F (quelques exceptions) Montage côte à côte Les appareils SmartVFD HVAC2 MI1-MI3 peuvent être installés Installation facile avec vis ou rails DIN côte à côte sans espace entre eux, soit avec des vis, soit sur rail...
  • Page 31 HVFDCDNEMA1FR4 Kit MI4 Nema 1 HVFDCDNEMA1FR5 Kit MI5 Nema 1 HVFD2DMOUNTKIT/U Kit de montage de la porte du SmartVFD HVAC2 HVFDCABLE/U Câble de mise en service du SmartVFD et adaptateur USB HVFDCDMCA/U Dispositif de mise en service du Compact HVFDCDMCAKIT/U Kit de mise en service du Compact (câble, adaptateur USB et dispositif combinés)
  • Page 32 Vous défendrez et indemniserez Honeywell, ses sociétés affiliées, filiales pour et contre toute responsabilité, frais ou dommages, y compris les honoraires d'avocats, résultant de quelque manière, ou survenant en connexion avec toute modification à la documentation de votre part.

Table des Matières