MAINTENANCE OF SPEC MIX
SILOS
®
d. Valve gate is clean and operates easily.
e. Discharge chute is not cut, torn or weathered.
f. Material flow basket is intact, clean and operational.
g. Legs are free of mortar build-up.
h. Top of silo is free of excessive mortar build-up.
i. Top hatch integrity is sound and free of defects, broken welds or supports and free of mortar
build up.
j. Safety ring connections are clean and free of hardened mortar or grout.
NOTE: Damaged silo legs affecting the integrity of the silo must be replaced immediately before
silo set up or any continued use.
NOTE: There is no replacement schedule for the silo lynch pins, unless a manufacture defect is
evident.
WARNING: Do not enter the interior of the silo cone for any inspection or maintenance. If
absolutely necessary, personnel must follow confined space entry procedures (OSHA).
20
Reducing Unnecessary Exposure to Dust at the Mixing Station
SPEC MIX silo delivery systems are designed to increase productivity on site while adding to job site
safety by reducing physical injury with their ergonomically correct design. The standard gravity silos
can also limit workers exposure to construction site mixing dust when the following best practices
are incorporated into every day use.
BEST PRACTICES FOR SPEC MIX
®
Loading the Silo :
1. Install the SPEC MIX Dust Containment Chute into
the fill port of the silo. The end of the tube with
the skirt should be positioned just above the top
of the silo and draped down to close any air gaps
between the dust containment chute and the silo.
2. Position the bulk bag over the top of the silo
centered over the fill port and safety ring so that the
dust containment chute meets up with the bottom
of the bulk bag.
3. Lower the bulk bag to a position just above the
safety ring, compressing the dust containment
chute.
SILOS
21