3.5 Maximum number of daily time bands
The heating program includes 6 daily time bands for the temperature level, numbered from 1 to 6. If necessary, they can be reduced to a minimum of 2.
1. Press the button
for 3 seconds.
2. The display shows parameter CU.
3. Press the button
4 times.
_________________________________________________________________________________________________________________________________________________
3.6 Heating minimum temperature
Follow the instructions below to set the heating circuit water minimum value in steps of 1°C.
1. Press the button
for 3 seconds.
2. The display shows parameter CU.
3. Press the button
5 times.
_________________________________________________________________________________________________________________________________________________
3.7 System filling
This function manages the operation mode of the electric device for filling the water circuit in certain boiler models.
1. Press the button
for 3 seconds.
2. The display shows parameter CU.
3. Press the button
6 times.
_________________________________________________________________________________________________________________________________________________
Attention: Set manual filling on the boiler control board. In manual operation and if the sensor installed in the boiler detects insufficient pressure, the bar icon will blink on the display;
pressing the button
will activate the special solenoid valve. During manual or automatic system loading, the bar icon will become steady. Once the nominal pressure has
been re-established, the remote control will return to the normal display.
3.8 Temperature unit of measure selection
Follow the instructions below to use the Remote Control in °C or in °F.
1. Press the button
for 3 seconds.
2. The display shows parameter CU.
3. Press the button
7 times.
4. The display shows parameter P6.
_________________________________________________________________________________________________________________________________________________
EN
82
4. The display shows parameter P3.
5. Press any other button to exit the menu.
4. The display shows parameter P4.
5. Press any other button to exit the menu.
4. The display shows parameter P5.
5. Press any other button to exit the menu.
5. Press any other button to exit the menu.
code 3541Z220 - Rev. 00 - 05/2021
Press the buttons
/
bands from 2 to 6.
Press the buttons
/
ments. By keeping the button pressed the value will change rapidly.
Set to 0 using the buttons
/
Set to 1 using the buttons
/
to 2 using the buttons
/
Set to 0 using the buttons
/
Set to 1 using the buttons
/
to change the number of daily time
to adjust the parameter in 1°C incre-
to deactivate the electric filling device.
to activate manual system filling. Set
to activate automatic system filling.
to select °C.
to select °F.