Dual Hood Installation Steps
Step 1
(A) Cut a 6" diameter hole in the exterior wall of the building.
(B) The top of the hole should be a minimum of 1" from the bottom of
the floor above (if applicable).
SIDE VIEW
of Exterior Wall
Step 3
(A) Insert the 6" galvanized duct through the hole cut in the exterior
wall. Slide in until the backplate is flush with the exterior wall (curved
side up).
(B) Level the backplate and drill 4 holes in the exterior wall.
(C) Seal the Backplate with exterior weatherproof sealant and screw
in place.
(D) Line up and hold the Screen in place using the guidelines.
(E) Snap on the hood cover.
(E)
SIDE VIEW
of hood cover
(D)
Screen
Step 5
Apply a generous bead of silicone:
(A) Silicone around the 6" galvanized duct at the interior wall.
(B) Silicone the groove of the internal divider located inside
the 6" galvanized duct.
(C) Silicone around the outer edge of the 6" galvanized duct.
(C)
(A)
Side View
Step 7
(A) Measure the distance from the interior wall to the duct splitter.
(B) Line up the 2 halves of the duct insulator to fit together.
(C) Use a blade knife to cut both halves of the duct insulator to the
measured distance.
(A)
(C)
SIDE VIEW
of the 2 halves of the
(C)
duct insulator
Floor
(B)
(A)
(C)
(A)
(B)
(B)
(B)
(C)
End View
of 6" galvanized duct showing
internal divider (internal divider
is vertical).
EXPLODED END VIEW
of duct insulator seam.
Step 2
(A) Remove the hood cover from the backplate.
(B) Slide the foam gasket around the 6" galvanized duct with the
white side of the gasket towards the backplate. Align and insert the
rounded side of the foam gasket into the rounded side of the
backplate.
SIDE VIEW
of hood cover
Step 4
For 5" Ducting, attach the two insulated 5" ducts from the unit over
the 5" Duct Collar (A). Secure the insulation to the 6" Duct Splitter
Collar Rim (B).
For 6" Ducting, secure the insulated 6" ducts from the unit over the
6" Duct Splitter Collar Rim (B).
TOP VIEW
of duct splitter
Step 6
(A) Attach the duct splitter over the 6" galvanized duct. Be sure the
pieces align with the holes located in the underside of the duct
splitter and 6" galvanized duct.
(B) Insert and attach the Retainer Screw Assembly until it seats in
the pre-punched hole in the galvanized pipe. The nylon should be
flush with the foam. Screw until secure (3 to 4 turns).
.
Step 8
(A) Silicone the concave sides of the duct insulator.
(B) Silicone both ends of the duct insulator.
(C) Align the cut ends of the duct insulators towards the exterior wall
and wrap the 2 halves of the insulator around the exposed 6"
galvanized duct.
(D)Secure the duct insulator with the Nylon Cable Tie.
(B)
(A)
EXPLODED END VIEW
of duct insulator seam.
Foam Gasket (rounded
side up, white side
Backplate
towards backplate)
(rounded side up)
(A)
(B)
SIDE VIEW
of 6" galvanized duct, foam
gasket and backplate
(B)
(A)
(B)
(A)
(B)
(B)
SIDE VIEW
of duct insulator
Front View
of Foam
Gasket
NOTE: Tape the duct
(A)
to the Duct Splitter
Collar. Do not drill.
(B)
(C)
(D)