Dual Hood - Kit Number 99-190
Intake and Exhaust Requirements for the
Dual Hood
● Minimuim 6' (2m) away from dryer vents, furnace
exhaust (medium or high efficiency furnaces),
driveways, oil fill pipes, gas meters, or garbage
containers
● At least 18" (457 mm) above the ground, or above the
depth of expected snow accumulation.
● At least 3' (1m) from the corner of the building.
● Do not locate in a garage, attic or crawl space.
Side View
Hood
Backplate
Foam Gasket
Hood
Stale Air Exhaust
Fresh Air Intake
Screen
Foam Gasket
Top View
Hood
CAUTION!
Sealant must be applied as per instructions or
leakage and condensation may occur.
Nylon
Cable Tie
Duct Insulator
Retainer Screw
Assembly
6" Galvanized Duct
Duct Insulator
Hood
6" galvanized
Backplate
duct
Included in this Kit
- Hood Assembly
- Foam Gasket
- Duct Splitter
- Duct Insulator (2 pieces)
- Retainer Screw Assembly
- Nylon Cable Tie
- Screen
Contact your local building authority before installation 
of the Dual Hood to verify compliance with local 
building codes. 
Duct Collar Rim
Duct Splitter
(Can be used for 6" ducting)
6" Duct Splitter Collar Rim
(Optional 6" duct Connection)
Duct Splitter
Nylon
Cable Tie
6" Duct Splitter Collar Rim
(Optional 6" duct Connection)
Insulate the Fresh Air Supply and Stale Air
Exhaust ductwork back to the unit.
ATTENTION!
5" Duct
Collar
Enlarged View
of Retainer Screw
Assembly
5" Duct Collar for
Stale Air Exhaust
5" Duct Collar for
Fresh Air Intake
ATTENTION!
98-TI-DualHood
IH 0611

Publicité

loading

Sommaire des Matières pour AIRIS 99-190

  • Page 1 Dual Hood - Kit Number 99-190 Included in this Kit - Hood Assembly Intake and Exhaust Requirements for the - Foam Gasket Dual Hood - Duct Splitter ● Minimuim 6' (2m) away from dryer vents, furnace - Duct Insulator (2 pieces)
  • Page 2 Dual Hood Installation Steps Step 1 Step 2 (A) Cut a 6" diameter hole in the exterior wall of the building. (A) Remove the hood cover from the backplate. (B) The top of the hole should be a minimum of 1" from the bottom of (B) Slide the foam gasket around the 6"...
  • Page 3 Dual Hood - Trousse Numéro 99-190 Inclus dans cette trousse Exigences relatives à l'admission et à l'évacuation pour le - Capuchon complet capuchon jumelé - Joint d'étanchéité en mousse • À un minimum de 6 pieds (2 mètres) de tout évent de - Séparateur du conduit...
  • Page 4 Marche à suivre pour installer le Dual Hood Étape 1 Étape 2 (A) Découpez un orifice de 6 pouces de diamètre dans le mur extérieur de (A) Enlevez le couvercle du capuchon de la plaque arrière. l'édifice. (B) Glissez le joint d'étanchéité en mousse autour du conduit galvanisé de 6 (B) Il devrait y avoir un espace d'au moins 1 pouce entre le sommet de ce trou po en tournant le côté...