• Audible Alarm (internal to the inverter) — The alarm makes a buzzing
sound when the inverter senses a low battery condition. The user should
reduce the AC load, charge the battery, and check the DC cable for
excessive losses.
• Ground Terminal — For attaching an insulated safety ground wire. This
safety wire is for protecting personnel if there is an unlikely failure in either
the cabling or enclosure insulation.
rear Panel
Cooling Fan
• Positive Terminal — Positive (+) DC Input (Red)
• Negative Terminal — Negative (−) DC Input (Black)
• Cooling Fan — High-speed and load controlled
load consIderatIons
The startup load of an appliance is a major factor of whether this inverter
can power it. This initial load is only momentary. With many appliances, it is
approximately twice the continuous load, but some appliance startup loads can
be as high as eight times the continuous load.