Important notes
The device's warranty will be invalid if it is installed for use with a solid-state wall switch or dimmer.
Control
It must only be used with the remote control provided with the unit.
According to the terms and conditions of our warranty, this fan can only be installed by a certified
electrician. Fans that are installed incorrectly can be dangerous to people and very expensive to re-
Installing the fan
pair, and will lose their warranty. This fan is designed for interior use only, excluding moist areas and
bathrooms. The supplier does not assume any liability for physical or bodily damage caused by the
incorrect use or installation of the fan. If you are unsure, consult an electrician.
Before informing the technical department, we recommend reading the troubleshooting guide inclu-
ded in this manual. Operating noise can be normal upon beginning to use this fan. Leave it on for at
Troubleshooting
least eight hours continuously for this noise to disappear. Some fans may wobble slightly, which does
not indicate any malfunction.
These devices have not been designed to be used by children; people with physical, sensory, or mental
disabilities; or people with little experience and knowledge, unless they are supervised or instructed
Danger
on adequate use by the people responsible for them, for their own safety. Children must be super-
vised to ensure that they do not play with this fan. Any unauthorized use and/or modification of this
apparatus may be dangerous to your health and safety.
Device technical specifications
Nominal voltage and frequency
Light wattage
Luminous flux
Light color temperature
Nº of light ON/OFF cycles
Nº of hours of light lifespan
Protection category
Protection index
Work temperature
Dimmable/Not dimmable
Maximum ceiling slope on which it can be installed
Light angle
Light Ra
Speed 1
Fan power (W)
Fan RPM
Fan airflow (m³/min)
Noise level (dB)
Speed 2
Speed 3
4.1
6.9
96
126
33
67
29
31
Installing a fan without a shaft, flush with the ceiling, can reduce airflow.
13
Speed 4
Speed 5
10.8
12.8
155
163
99
119
38
44
EN
220-240V~AC 50Hz
24W
2300lm
2700/4500/6000K
10000
25000h
Class I
IP20
-20 ↔ 45º
Not dimmable
25º
120º
>80
Speed 6
18.8
25.3
188
206
144
161
48
52