2.1.5. TABLEAU DES PARAMÈTRES
PARAMÈTRE
DESCRIPTION
P00
SELECTION DE LA PUISSANCE
P01
SELECTION DU TYPE DU GAZ D'ALIMENTATION
NOTE:
LIRE ATTENTIVEMENT LES INSTRUCTIONS CONTENUES DANS
LE CHAPITRE 'TRANSFORMATION DU GAZ' AVANT DE MODIFIER
LE PARAMETRE.
P02
SÉLECTION DU MODE DE FONCTIONNEMENT
NOTE:
SI LA VALEUR DU PARAMETRE EST REGLEE SUR "2", ASSUREZ-
VOUS QUE LA VANNE A TROIS VOIES EST EN POSITION DE
RECIRCULATION, COMME DECRIT DANS LE CHAPITRE
"RECIRCULATION EN MODE MIXTE".
MINUTAGE POST-CIRCULATION (RECIRCULATION DESACTIVITEE)
P03
A TRAVERS CE PARAMETRE, IL VOUS SERA POSSIBLE DE
SELECTIONNER LE FONCTIONNEMENT DE LA POMPE EN
PRODUCTION D'E.C.S., APRES LA FERMETURE DU ROBINET.
P04
MINUTAGE POST-CIRCULATION (RECIRCULATION ACTIVE)
A TRAVERS CE PARAMETRE, IL VOUS SERA POSSIBLE DE
SELECTIONNER LE FONCTIONNEMENT DE LA POMPE EN
PRODUCTION D'E.C.S., EN CAS DE RECIRCULATION ACTIVE
APRES LA FERMETURE DU ROBINET.
2. PREMIÈRE MISE EN ROUTE
PLAGE
SFK 57 - RAD - FRA - Manuel Inst. - 2007.1_CSA
FONCTION
0 - 3
0 = 24 KW
1 = 28 KW (SFK 57)
2 = 34 KW
3= 55 KW (SFK 55 - SFK 56)
0 - 1
0 = GAZ NATUREL
1 = L.P.G.
0 - 4
0 = CHAUFFE-EAU
1 = CHAUFFE-EAU AVEC
RESERVOIR INDIRECT
2 = MODE MIXTE (ECS +
CHAUFFAGE) - SFK 56
3 = MODE MIXTE (ECS +
CHAUFFAGE) AVEC RESERVOIR
-
SFK 57
4 =
N.A.
0 - 90
VALEUR EXPRIMÉE PAR
MULTIPLES DE 5 SECONDES
(RÉGLÉ EN USINE À 12 X 5 = 60
SECONDES)
0 - 90
VALEUR EXPRIMÉE PAR
MULTIPLES DE 5 SECONDES
(RÉGLÉ EN USINE À 8 X 5 = 40
SECONDES)