Télécharger Imprimer la page

Philips GreenPower TLED InstantFit Lamp Guide D'installation Rapide page 2

Publicité

List of compatible ballasts / List de ballasts compatibles
Philips Advance Models: GOPA-2P32-SC, GOPA-4P32-SC, GOPA-2P32-LW-SC, GOPA-4P32-LW-SC, IOPA-2P32-N, IOPA-4P32-N,
IOPA-2P32-LW-N, IOPA-4P32-LW-N, IOP-2P32-N, IOPA-4P32-N, IOPA-2P32-LW-N, IOPA-4P32-LW-N, ICN-2P32-N, ICN-4P32-N
ULT Models: B2321347HP-A, B4321347HP
GE Models: GE232MAX347-N, GE432MAX347-N
UltraSave Models: UT232347, UT432347
Installation guide / Guide d'installation
1
Switch-off power to the luminaire / Coupez
l'alimentation du luminaire.
4
Install the Philips GreenPower TLED InstantFit lamp
(one for each fluorescent lamp removed) / Installer
la lampe GreenPower TLED InstantFit Philips (une
pour chaque lampe fluorescente retirée.
Note / Remarque:
* 1) Confirm that the ballast in the luminaire (typically located in the ballast channel) is an instant start ballast mentioned in the list above /
Si le ballast n'est pas un ballast à allumage insantané, veuillez arrêter et contacter le fabricant. Autrement, passez à l'étape 2).
2) Verify the fluorescent tube type is listed on the label of Philips LED T8 InstantFit lamp / Vérifier que le ballast dans le luminaire est un ballast
à allumage instantané (généralement situee dans le canal dus ballast).
Specification and ordering information / Spécifications et information de commande
Philips GreenPower TLED
Deep red/white (DR/W)
GreenPower TLED DR/W 14.5W MB InstantFit UL/CSA
Deep red/white/far red (DR/W/FR)
GreenPower TLED DR/W/FR 14.5W MB InstantFit UL/CSA
Lifetime and maintenance values are given at an ambient temperature of 25 °C, and a photon flux maintenance of 70%. / Les valeurs de durée de vie et de
maintenance sont indiquées pour une température ambiante de 25 °C et une maintenance de flux de photons de 70%.
The light output and power consumption are based on the optimal (reference)driver; Philips ICN-1P32-N. / Le rendement lumineux et la
consommation sont basés sur le driver optimal (de référence) : Philips ICN-1P32-N.
The use of a different driver will lead to different values in lightoutput and (system)power consumption. / L'utilisation d'un autre driver entraînera
des valeurs différentes en rendement lumineux et en consommation (du système).
© 2014 Royal Philips N.V.
All rights reserved. Reproduction in whole or in part is prohibited without the prior
written consent of the copyright owner. The information presented in this document
does not form part of any quotation or contract,is believed to be accurate and reliable
and may be changed without notice. No liability will be accepted by the publisher for
any consequence of its use. Publication thereof does not convey nor imply any license
under patent or other industrial or intellectual property rights.
Document order number: 3222 635 69454
01/2014
www.philips.com/horti
2
Remove diffuser (if provided) / Retirez le diffuseur
(si inclu).
5
Replace diffuser (if removed in step 2) /
Remplacement le diffuseur (si inclu).
Photon flux
(typical) µmol/s
per module
20
tbd
3
Remove the existing fluorescent lamps from the
luminaire / Retirez les lampes fluorescentes *.
6
Switch on power to the luminaire / Allumez
l'interrupteur du luminaire.
Power
Lifetime
Ordering
consumption
hrs
code
W
12NC
14.5
25,000
9290 008 96406
14.5
25,000
9290 008 96506
Philips Lighting
A division of Philips North
America
200 Franklin Square Drive
Somerset, NJ 08873
Phone: 855-486-2216
Ordering
code
6NC
259 358
259 374
Philips Lighting
A division of Philips Canada
281 Hillmount Road
Markham, Ontario
Canada L6C 253
Phone: 800-555-0050

Publicité

loading