Models: ALN-T02-2L3S-GA
**IMPORTANT**
GUIDELINES TO ASSURE SAFE AND PROPER OPERATION OF YOUR TABLE
INSTALLATION GUIDELINES:
- Never open the A/C Control Box.
- Only use supplied Power Cable.
- Do not install table on an uneven surface.
- Do not install table in dusty or humid locations.
- Never lean on or apply excessive weight to table while in operation.
- Prevent wires from becoming caught in the mechanisms by securing them with the supplied clips and ties. Keep motor
area clear from wires and any other objects at all times.
- Only use a dry or damp cloth to clean Control Box. Before cleaning UNPLUG from power source.
- Check that all connectors are securely plugged in; remote wire and motor(s) wire(s) and A/C Control Box.
RESET INSTRUCTIONS
1) Hold down "
" button for 5 seconds.
2) The readout will show 'ASF.'
3) Release the button.
4) Press and hold the "
"button. The table will descend to its lowest level, stop, and rise until reaching default height - the
readout will now show numbers instead of 'ASF.' DONE!
****LOWEST LEVEL POSITION MUST BE REACHABLE. Path must be clear of obstructions when lift table is descending,
it cannot hit a stop before lowest LEVEL position otherwise reference is stored at the wrong height. ****
AFTER RESET, run full UP and DOWN cycles several times to ensure problem is solved.
OTHER ISSUES AND SOLUTIONS:
If ONE LEG is higher than the OTHER:
1) Unplug Power
2) Swap the left motor connector with the right motor connector on the A/C Control Box.
Repeat RESET procedure.
If there is no change, the problem is with the MOTOR LEG.
If the change results in the same problem but with the other leg, the problem is with the A/C CONTROL BOX.
Do not hesitate to contact us if you run into any problems during the procedure, or if you need a replacement:
MOTOR LEG or A/C CONTROL BOX.
Thanks!