Leak Testing Valves, Hoses and Regulator
1. Turn all control knob(s) to OFF.
2. Be sure regulator is tightly connected to LP tank.
3. Completely open LP tank by turning valve counter clockwise. If you hear
a rushing sound, turn gas off immediately. There is a major leak at the connection.
Correct before proceeding.
4. Brush soapy solution onto indicated connections shown at right.
5. If "growing" bubbles appear, there is a leak. Close LP tank valve immediately and
retighten connections. If leaks cannot be stopped, do not try to repair. Call for
replacement parts. Order new parts by giving the serial number, model number and
name of items needed to the Service Center at 800.251.0001
6. Always close LP tank valve after performing tank leak test by turning valve clockwise.
7. Do not use appliance until leak checked.
8. If you cannot stop a gas leak, immediately close LP tank valve and call
LP gas supplier or your fire department!
SERVICE SAFETY
PROPANE FUEL IS HIGHLY FLAMMABLE AND
UNDER PRESSURE.
• Do not store in temperatures over
120 degrees Fahrenheit
• Never use a flame to check for leaks. Use soapy
water.
• Keep out of the reach of children at all times.
Replacement Parts Available:
1
3
FOR YOUR SAFETY: IF YOU SMELL GAS:
1. Do Not attempt to light appliance
2. Extinguish any open flame
3. Disconnect from fuel supply
Replacement Parts List
1
35455
2
35456
3
35457
4
35458
2
Universal Burner
Valve
Manifold + Valve
(F235830)
Manifold+ Valve
(F235835)
4
7

Publicité

loading

Ce manuel est également adapté pour:

Base camp f235830Base camp f235835