2. Install transformer into hood canopy by lining up the 2 holes on the
flange of the transformer with the 2 screw studs in the top left side
of the hood canopy. Use 2 of the included #8-32 screws to make the
connection and fully tighten (Figure 2).
3. Loosely install the two #10-32 serrated flange nuts (included) onto the
studs located inside the top center of the hood.
4. Lift blower up into the hood canopy and slide the keyhole slots in the
blower mounting flange over the two studs of the hood. Slide the blower
into place and tighten the hex nuts on the mounting stud while lining up
the 8 holes in the blower mounting flange to the 8 screw studs of the
hood (Figure 3).
5. Using 8 of the included #8-32 screws, flat washers and star washers,
mount the blower in place and tighten all screws. Confirm that the
blower is securely seated in place and there are no air gaps around the
blower gasket.
6. Plug the 3 wire quick connect cord from the blower into the receptacle
on the range hood canopy. Plug the 4 wire quick connect cord from the
blower into the receptacle on the transformer. Plug the 4 wire quick
connect from the transformer into the receptacle on the range hood
canopy. These cords will only fit into the receptacles one way (Figure 4).
7. Reinstall the rear bottom plate by fitting the back edge of the plate into
the channel located on the back of the hood and reinstalling the two nuts
and washers removed in Step 1 (Figure 6).
Bottom Plate
Figure 6
672018 Rev. H 1-16
Nut
Washer
SECTION 4
Finishing the Installation
1. Install the included fuse into the electrical panel by turning the fuse cap
counter clockwise and pulling out. Insert the included 1/4" x 1-1/4"
time delay fuse in the holder and reinstall into the panel (Figure 7).
Cap
Figure 7
NOTE: If you need to replace the fuse, replace with a 1/4" x 1-1/4" Bussman
MDA-10 or equivalent 10 amp, 250V ceramic, time delay fuse only.
2. Refer to the hood instruction manual to complete the installation, for
maintenance, and before restoring power.
3. The blower is covered under the range hood's warranty.
CALIFORNIA RESIDENTS ONLY:
WARNING:
A CHEMICAL [OR CHEMICALS] KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER.
WARNING:
A CHEMICAL [OR CHEMICALS] KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE REPRODUCTIVE TOXICITY.
www.airkinglimited.com
Fuse
THIS PRODUCT CAN EXPOSE YOU TO
THIS PRODUCT CAN EXPOSE YOU TO
3 of 8

Publicité

loading

Ce manuel est également adapté pour:

Profesional b900Profesional b1125