Error Codes
No Code
Errors
E1
Control box
does not receive
1
E2
signals from
each leg sensor
E3
The table has
been used for
2
HOT
too long or
continuously
Height difference
3
E6
between
both legs
4
E7
Overload
Controller
beeps but
No signal from
5
does not
the control box
turn on
The buttons
work but
Control box
6
the control
is damaged
box does not
respond
Burning
7
Short circuit
odor
February 19, 2021
Steps Troubleshooting
• Reduce or recenter the load on the
1
table.
• Then reset the table.
• Disconnect and reconnect the wire
2
connecting the leg to the control box..
• Then reset the table.
• Switch the legs extension cords. Put
E1 into E2 or E2 into E3 & E3 into E1.
3
• If it still does not work, the wire is
damaged. Replace the wire.
• Then reset the table.
4
• Replace the control box.
• Replace the leg with a new one
5
OR resolder the circuit board wire.
• Then reset the table.
• Replace the leg with a new one
6
OR resolder the circuit board wire.
• Then reset the table.
• Wait 18 minutes. After this rest time,
the table will be ready for use.
N/A
• If urgent : Unplug the table for 45
seconds. Plug in and it will return to
normal.
• Reduce the load on the table.
1
• Then reset the table.
• Connect the wire properly to fix the
problem..
2
• The manual reset procedure may
be required.
• Replace the control box.
3
• Ensuite, réinitialisez la table.
• Replace the leg with a new one.
4
• Then reset the table.
• Reduce the load on the table.
N/A
• Then reset the table.
N/A
• Program the control pad..
• Replace the control box with
N/A
a new one.
• Then reset the table.
• Replace the control box with
1
a new one.
• Then reset the table.
ATTENTION : AFTER REPAIRING OR REPLACING COMPONENTS,
PERFORM THE MANUAL RESET PROCEDURE.
LOGIFLEX | ELEVATION PLUS - USER'S GUIDE
Reasons
E1 : The leg connected to the M1 port is supporting too much weight.
E2 : The leg connected to the M2 port is supporting too much weight.
E3 : The leg connected to the M3 port is supporting too much weight.
E1 : The leg connected the M1 port is not connected properly.
E2 : The leg connected the M2 port is not connected properly.
E3 : The leg connected the M3 port is not connected properly.
E1 : The wire connected to the M1 port is damaged.
E2 : The wire connected to the M2 port is damaged.
E3 : The wire connected to the M3 port is damaged.
The control box is damaged.
E1 : The wire connecting the leg's circuit board to the M1 port is damaged.
E2 : The wire connecting the leg's circuit board to the M2 port is damaged.
E3 : The wire connecting the leg's circuit board to the M3 port is damaged.
E1 : The circuit board of the leg connected to the M1 port is damaged.
E2 : The circuit board of the leg connected to the M2 port is damaged.
E3 : The circuit board of the leg connected to the M3 port is damaged.
When the desk is used for more than 2 consecutive minutes, the display will
say "HOT" to prevent overheating..
One of the legs is suppporting more weight than the other which causes a
height difference.
The wire of one of the legs is not connected, causing a difference in height..
The control box is damaged causing a difference in height. This can cause a leg
to move faster than the the other during a reset procedure.
The wire connected to the circuit board is damaged.
There is too much weight on the table.
The control pad has not been programmed.
The components or circuit board of the control box are damaged..
The control box is damaged.
Error Level
Low
Low
Medium
High
High
High
Low
Low
Medium
High
High
Low
High
High
High