digigard DG85 Guide D'installation page 6

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

In Relay Mode the detector's settings can only
be modified using the DIP switches and trim
pot.
DGP2 Mode: (DIP Switch 1 = ON)
When set to DGP2 Mode, the Digigard DG85
functions like a DGP2 motion detector module
by communicating alarm signals, tamper
signals, data and detector settings via the
combus.
The Digigard DG85 connects directly to a
Digiplex or DigiplexNE control panel's 4-wire
combus. Connect the four terminals labeled
RED, BLK, GRN and YEL to the
corresponding terminals on the control panel
(Figure 2 on page 27). The detector's relay
output always remains active even when set
to DGP2 Mode and can be used to activate
other devices.
In DGP2 mode, the motion detector can be
modified using the DIP switches and trim pot
or by entering Module Programming Mode via
an LCD keypad: For section numbers refer to
the detector settings on the back cover.
1. Press and hold the [0] key.
2. Enter your [
3. Enter section [953] (Digiplex) / [4003]
(DigiplexNE).
4. Enter the detector's 8-digit [
(located on PCB cover).
4 Digigard DG85
INSTALLER CODE
].
SERIAL NUMBER
]

Publicité