General Information; Functional Description - Ingersoll Rand D12IN-A Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Correction by the Company of nonconformities whether patent or latent, in the manner and for the period of time provided
above, shall constitute fulfillment of all liabilities of the Company for such nonconformities whether based on contract, warranty
negligence, indemnity, strict liability or otherwise with respect to or arising out of such Equipment.
The Purchaser shall not operate Equipment which is considered to be defective, without first notifying the Company in writing
of its intention to do so. Any such use of Equipment will be at Purchaser's sole risk and liability.
Note that this is Ingersoll Rand standard warranty. Any warranty in force at the time of purchase of the equipment or
negotiated as part of the purchase order may take precedence over this warranty.

1.1 FUNCTIONAL DESCRIPTION

Ingersoll Rand refrigerated air dryers remove moisture from compressed air. Moisture is detrimental to pneumatically
operated appliances, controls, instruments, machinery and tools.
Compressed air enters the patented aluminum heat exchanger where it is cooled down to the dew point temperature in
two different stages: In the first air/air sector compressed inlet air is cooled thanks to the colder compressed air coming
out counterflow from the condensate separator. In the second refrigerant / air sector, compressed air temperature is
further lowered to the dew point temperature. During this two stages almost all the oil and water vapours contained in
compressed air are condensed to liquid and successively be separated from the compressed air in the condensate
separator and drained out by the automatic drain. At this point the obtained cold air re-enters counterflow the initial air / air
exchanger and it is reheated by the inlet hot air with the consequence of energy recovering and also reduction of the
relative humidity contained in the outflowing air.
This dryer can be easily installed into various pneumatic systems in which dry air is required or desired. Please refer to
Start up chapter for complete operating details.
The dryer comes provided with all the control, safety and adjustment devices, therefore no auxiliary devices
are needed.
A system overload not exceeding the maximum operative limits can worsen the operational performance of the
dryer (high dew point), but it will not affect its safety.
The electric diagram (attachment B) shows the minimum protection degree IP 42.
Improper grounding can result in electrical shock and can cause severe injury or death.
This product must be connected to a grounded, metallic, permanent wiring system or an equipment-grounding
terminal or lead on the product.
All grounding must be performed by a qualified electrician and comply with national and local electrical codes.
In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape
wire for the electric current.
Ground must be established with a bare grounding wire sized according to the voltage and minimum branch
circuit requirements.
Ensure good bare metal contact at all grounding connection points, and ensure all connections are clean and
tight.
Check grounding connections after initial installation and periodically thereafter to ensure good contact and
continuity has been maintained.
Check with a qualified electrician or service technician if the grounding instructions are not completely
understood, or if in doubt as to whether the product is properly grounded.
1.2 USE OF THE MACHINE IN SAFE CONDITIONS
This system has been designed and manufactured in compliance with the European safety directive in force and
UL/ULC, therefore any installation, use and maintenance operations must be performed respecting the instructions
contained in this manual.
Because an air dryer is pressurized and contains rotating parts, the same precautions should be observed as with any
piece of machinery of this type where carelessness in operation or maintenance could be hazardous to personnel. In
addition to obvious safety rules that should be followed with this type of machinery, safety precautions as listed below
must be observed.
1. Only qualified personnel shall be permitted to adjust, perform maintenance or repair this air dryer.
2. Read all instructions completely before operating unit.
3. Pull main electrical disconnect switch and disconnect any separate control lines, if used, before
attempting to work or perform maintenance on the unit.
4. Do not attempt to service any part while machine is in an operational mode.
5. Do not attempt to remove any parts without first relieving the entire air system of pressure.
6. Do not attempt to remove any part of the refrigeration system without removing and containing
refrigerant in accordance with the EPA and local regulations.
7. Do not operate the dryer at pressures in excess of its rating.
8. Do not operate the dryer without guards, shields and screen in place.
9. Inspect unit daily to observe and correct any unsafe operating conditions.
Cod. 710.0138.39.00 Rev03 – 02.2012

1. GENERAL INFORMATION

3 - 30

Publicité

Table des Matières
loading