Installation
Switch off appropriate mains fuse and master switch!
Take the wall switch out of the wall box.
Disconnect all wires from the switch.
Connect the live (brown) and load wire (black) to the terminals of the LW12 as described
in figure A.
Connect the wire from the In-Wall module to the switch.
Replace your normal make/break contact switch by a momentary switch.
Connect a load wire (brown) to the momentary switch (CAUTION: In the interest of safety
and to make the device work properly, this load wire HAS TO be from the same group).
Connect a black wire to the output of the switch. Connect the other end of this black
wire to the input K of the LW12 MicroModule. See figure A.
Place the module against the back of the wall box and replace the switch inside the box.
Switch on mains fuse and master switch.
Programming
Programming the address and the optional functions All Lights On/All Lights Off/All Units Off:
To change the address and the settings for the All Lights On/All Lights Off/All Units Off
functions, the module needs to be set to the program mode.
Activating the program mode can be done in 2 ways:
1.
By transmitting On / Off commands of the set address in quick succession (e.g. if the
address is B2: B2 ON, B2 OFF, B2 ON, etc.) After the LW12 has changed state 5 times,
with no more than 1.5 seconds between changes, the LW12 will no longer respond,
which means the module is set to the program mode.
2.
By quickly pressing/switching the momentary switch connected to the module. After the
LW12 has changed state 5 times, with no more than 1.5 seconds between changes, the
LW12 will no longer respond, which means the module is set to the program mode.
Once in Program Mode the new address can be set by sending an "Address" or "Address
On" (e.g. B2 ON) or "Address Off" command for the new address code twice (using any
Marmitek X-10 controller). If you want to change the code again, just send the revised
code twice as before.
To set the unit to respond to "All Lights On" and/or "All Lights Off" and/or "All Units Off"
just send these commands twice for the new address code (using any X-10 controller).
Please note: The "All Lights On/All Lights Off /All Units Off" options can be disabled by
setting a new address or by returning to the Default Setting.
Resetting the LW12
When leaving the factory, the LW12 is set to the default address A1 en does not respond to
the optional functions All Lights On/All Lights Off/All Units Off. If the address and settings for
the options "All lights on/All lights off /All Units Off" aren't known, the default address of A1
can be set by applying power to the unit and sending the address P16 to the unit twice
(using any X-10 controller - i.e.: TM13 + RF remote control).