G
B
AERIAL
COAX
R=2,2KΩ
SIGNAL
BUZZER
+
-
24 Vdc for
AUTOTEST
+
EDGE
-
24 Vdc for
+
-
ACCESSORY
SUPPLY
POINT B - SETTINGS
DIP 1
(ON) MOTOR ROTATION DIRECTION CHECK (See Point C)
DIP 2
(ON) PROGRAMMING (See Point D)
DIP 1-2 STORAGE/DELETION OF RADIO CODES FOR COMPLETE
OPENING (DIP 1 ON followed by DIP 2 ON) (POINT G) ONLY FOR
CRX MODELS
DIP 1-3 STORAGE/DELETION OF RADIO CODES FOR PEDESTRIAN OPENING (DIP 1 ON
followed by DIP 3 ON) (POINT H) ONLY FOR CRX MODELS
DIP 2-1 PROGRAMMING OF THE PEDESTRIAN OPENING (See Point F)
DIP 3
ON - Automatic Closing ENABLED
OFF - Automatic Closing DISABLED
DIP 4
ON - Photocells active only in closing
OFF - Photocells always active
DIP 5
ON - blinker pre-flashing
OFF - blinker normal-flashing
DIP 6
OFF - STEP BY STEP
PHOTOCELL
EDGE
+
K BUTTON
PED. BUTTON
COM
ELECTRIC
LOCK
POWER SUPPLY
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
ON - AUTOMATIC
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
DIP 7
ON - low speed in approaching ENABLED
OFF - low speed in approaching DISABLED
DIP 8
ON - electric lock command ENABLED
OFF - electric lock command DISABLED
DIP 9
ON - Hammering on complete close position to ease Manual Release
- Hammering before opening to ease electric lock unlocking
OFF - no impulse
DIP 10
ON - Extra thrust when reached closing position to make sure that the mechanical
bolt is fixed into the ground
22
BLINKER
MOTOR 2
CAPACITOR M2
MOTOR 1
CAPACITOR M1