Fanaway LED EVO1 Installation Instructions
PREPARE AND COMPLETE THE ELECTRICAL WIRING --- WIRING DIAGRAM (FIG. 9)
WARNING: FOR YOUR SAFETY ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A LICENSED
ELECTRICIAN.
NOTE: AN ADDITIONAL ALL POLE DISCONNECTION SWITCH MUST BE INCLUDED IN THE FIXED WIRING.
USE WITH WALL SWITCH WIRING DIAGRAM:
Fig. 9
Wiring requirement at the terminal block:
The switched active wire out from the rotary switch speed control "F" to the "L" terminal of the terminal block on the
mounting bracket.
The switched active wire out from wall controller "light" switch, to the "LA" terminal of the terminal block on the
mounting bracket.
Supply Neutral to "N" terminal of the terminal block on the mounting bracket.
Earth to "
" terminal of the terminal block on the mounting bracket.