NOT E
will not guarantee compatibility of the cited oils with OL150 in the event of a change in
the formulation by the producers of these oils; in particular, it will not guarantee compliance with ISO
10592 relating to hydraulic steering systems.
performance and/or duration.
In the days immediately following the filling, you need to monitor the oil level in the tank; if necessary,
top up the system.
Initially, the oil level may drop, as small amount of air initially emulsified in the fluid may
disperse. Perform the different bleeding procedures, as described below.

3.4.1 Positioning the oil bottle

The oil filler kit will be needed in order to carry out this operation (1 pin, 1 transparent pipe, 1 hose
carrier fitting and 1 oil bottle spout), NOT supplied as standard.
• Remove the cap from the pump and insert the filling adapter.
• Attach a nozzle to a new bottle of hydraulic oil, connecting the hose from the fill port to
the spout of the bottle.
• Turn the bottle and pierce it with a pin, as indicated in the figure, so as to facilitate the passage
of oil to the pump.
• Fill the pump until no air bubbles are no longer visible in the hose.
NOTE
At the time of oil bottles replacement, during
the filling process, close all bleed valves of the
cylinder.
To empty the system, make sure the filling hose
always contains oil. If during bleeding air gets
into the system, the whole process must be
repeated from the beginning.
NOTE
Replace the bottle before its empties and use
recovered oil only after 24 hours.