Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The product may only be used for bathing, hygienic and body cleaning pur-
poses.
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be observed.
• The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be
altered if required. In this case, pay attention to the fact that a change of instal-
lation height will also change the minimum height, and that the altered mounting
dimensions must be taken into consideration.
• During installation of the product by qualified trained personnel, make sure that
the entire fastening surface is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the product and has no weak
points.
• The filter insert must be use to protect the shower against incoming dirt by pipe-
work. Incoming dirt leads to defects or/and can damage parts of the shower;
such caused faults voids all liability and guarantee claims.
• The product is not designed to be used with steam baths!
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G 1/2:
Thermal disinfection:
Safety against backflow
The product is exclusively designed for drinking water!
4
English
max. 1 MPa
0,15 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
150±12mm
cold right - hot left
max. 70°C / 4 min
Assembly see page
Symbol description
Do not use silicone containing acetic acid!
Safety Function (see page )
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
Adjustment (see page )
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Maintenance
• The mixer is equipped with check valves. The check valves must be
checked regularly according to DIN EN 1717 in accordance with
national or regional regulations (at least once a year).
• To guarantee the smooth running of the thermostat, it is necessary
from time to time to turn the thermostat from total hot to total cold.
Dimensions (see page
Flow diagram (see page
Hand shower
overhead shower
Operation (see page
To empty the overhead shower after use, hold it in a slightly inclined
position.
Cleaning (see page
Spare parts (see page
Special accessories (order as an extra)
tile-matching-disk chrome plated #93146000 (see page
)
)
)
)
)
)