INSTALLATION
REMOVE ONE
ELECTRICAL
KNOCKOUT
1.
Run power cable to installation location. Remove one knock-
out from rough-in plate wiring box.
I
VERTICAL DISCHARGE
(WP28M, WP29M,
P29M)
HORIZONTAL DISCHARGE
(WP28M & WP29M only)
2.
Attach ROUGH-IN PLATE to MOUNTING STUDS at inside,
top of hood with (4) existing #10-32 HEX NUTS.
ROUGH-IN PLATE
GROUND WIRE
TO GROUND
SCREW
3.
Remove wiring cover.
4.
Connect cable to wiring box using proper connector. Connect
BLACK TO BLACK (hot), WHITE TO WHITE (neutral) and
GREEN OR BARE WIRE (ground) under second ground
screw. Replace wiring cover.
5.
Run 10" round steel duct to installation location.
MODEL 421
10-IN. DAMPER
(INCLUDED)
6.
Install 10" damper (Model 421, included) inside the vertical
ductwork that will be attached to the rough-in plate. Do not
install in a horizontal ductwork or directly on top of the adapter
or it will not open and close properly.
Remove shipping tape if present. Secure the damper to the
duct with 3 - #8 sheet metal screws (not provided). Ensure
the damper opens and closes freely. Seal all joints with metal
foil duct tape to eliminate air leaks.
NOTE: To optimize airflow and reduce noise, position the
damper at least 17" above the top of the rough-in plate - or
as far as the duct run will allow.
MODEL iQ12
Page 3
BLACK TO BLACK
WHITE TO WHITE
17" MIN.