During this period Studer will repair the defective product free of charge.
Studer is not responsible for any costs of the transport of this product.
This warranty is void if the product has suffered any physical damage or
alteration, either internally or externally, and does not cover damage
arising from improper use
This warranty will not apply where the product has been misused,
neglected, improperly installed or repaired by anyone other than Studer.
Studer is not responsible for any loss, damage or costs arising from
improper use, use in an unsuitable environment or improper installing,
setup and malfunctioning of the product.
Since Studer cannot control the use and installation (according to local
regulations) of their products, the customer is always responsible for the
actual use of these products. Studer products are not designed for use
as cricital components in life support devices or systems, that can
potentially harm humans and/or the environment. Studer keeps the right
to change product specifications without previous notice.
1)
Examples of improper use are :
- too high input voltage applied
- wrong shunt connection
- applying battery voltage to shunt input
- mechanically stressed enclosure or internals due to harsh handling
and/or incorrect packaging
- contact with any liquids or oxidation caused by condensation
6. TECHNICAL DATA
Supply voltage range
Supply current @Vin=24VDC
Input voltage range
Input current range
20
1)
or from use in an unsuitable environment.
SBM-01 TECHNICAL DATA
without BL
@Vin=12VDC
without BL
SBM-01 high precision battery monitor
9 .. 35VDC
6mA
8mA
0 .. 35VDC
-500 .. +500A