Pre-Operation (continued)
INSTALLING FILL CAP/BREATHER
□
Compressor pump is filled with high quality oil at
the factory. Remove the plug (1) from the oil fill
port. Install the provided fill cap/breather (2) into
the oil fill port.
REFILLING THE COMPRESSOR PUMP WITH OIL
WARNING: Drain the tank to release all the tank air
pressure before removing the oil fill cap. Be sure the air
vent in the oil fill cap is free from debris. If the air vent
is blocked, pressure can build in the crankcase, causing
damage to the compressor and possible personal injury.
□
Remove the oil fill cap/breather (3) by turning it
counter-clockwise by hand. Fill the compressor
pump with air compressor oil, such as SAE-30 non-
detergent Semi Synthetic oil, at slow intervals until
the oil reaches the center of the red circle in the
sight glass (4). Use SAE-10 during extreme winter
conditions.
ATTACHING THE HOSE
WARNING: Do not attempt to modify this product or
create accessories not recommended for use with this
product. Any such alteration or modification is misuse
and could result in a hazardous condition leading to
possible serious personal injury.
WARNING: Do not attach the air chuck or other tools
to the open end of the hose until start-up has been
completed.
WARNING: Do not allow familiarity with products to
make you careless. Remember that a careless fraction
of a second is sufficient to inflict serious injury.
WARNING: Always wear safety goggles or safety
glasses with side shields when operating power tools.
Failure to do so could result in objects being thrown
into your eyes resulting in possible serious injury.
The compressor is assembled at the factory and
ready for use. Check all components to ensure secure
assembly, (such as rubber feet, handle, quick connects,
gages, safety valve, air filter, drain valve, etc.)
□
Make sure the power to the air compressor is
disconnected.
□
Apply thread tape to the threaded connections
of the hose (not included), and attach the quick
connect to the hose using a wrench (not included).
□
Rotate the pressure regulator knob (1) fully
counterclockwise.
□
Insert the hose adapter end of the air hose (2) into
the female coupler end in the air compressor (3).
1
3
11
Please contact 1-888-895-4549 for further assistance.
2
3
2
industrialaircontractor.com
4
1