inStallation inStruCtionS
UNIT INSTALLATIoN
WarninG
risk of personal injury. Do not lift or move
unit without appropriately rated equipment.
Be sure the unit is securely attached to lifting
device used. Do not lift unit by holding onto
tubes or coolers. Do not use unit to lift other
attached equipment.
It is extremely important to install the compressor in a clean, well-ventilated area where the
surrounding air temperature will not be more than 100°F. Do not locate the compressor air inlet near
steam, paint spray, sandblast areas or any other source of contamination.
1. Unbolt the unit from the shipping skid. Use a ratchet
with a 9/16 inch socket. Remove the unit from the
skid. This requires at least two people - one person
to walk the unit off the skid and one to help maintain
balance so the unit does not topple. Place the unit
where you plan to install it (at least 18 inches from
any wall or surface).
2. Place pre-drilled vibration pads under each foot
(part number: PA300600AV) to avoid unnecessary
vibration which could damage the unit.
Call 1-888-3KoBALT (1-888-356-2258) to order
vibration pads.
Using the mounting holes and the holes of the
vibration pads as a guide, drill holes into concrete
using a 3/8 inch masonry bit. Holes drilled must be at
least 5 inches into the concrete.
notiCe
unit Care and maintenance. This compressor
is not intended for outdoor installation.
1
2
8
18 inches