Replacement Parts
Charts (60/pack)
KT6 Ranges
-50 to +50°F/°C
0 to +50°F/°C
0 to -50°F/°C
50 to +100°F/°C
0 to +100°F/°C
0 to -100°F/°C
0 to +250°F/°C
0 to +500°F
NOTE: 0 to -100°F/°C & 0 to 100°F/°C use the same chart numbers (C657 & C658)
0 to -50°F/°C & 0 to 50°F/°C use the same chart numbers (C653 & C654)
Accessories/Probes
Pens (6 red)
Pens (3 red & 3 blue)
6" High Temperature Basic Probe, +2100°F
1/8" Compression Fitting for D164 probe
6" Stainless Steel Basic Probe (316SS), +1650°F
Replacement Bead Probe, Type "K", +500°F
4" Piercing Probe, 5' coiled cable, +1650°F
5" Immersion Probe, 5' coiled cable, +1650°F
10' Straight Extension Cable
100' Straight Extension Cable
1-Pt. NIST traceable certificate of calibration
3-Pt. NIST traceable certificate of calibration
One year extended warranty
*Must be requested when ordering, add one week to delivery time.
Troubleshooting
Symptom
Pen trace too
fine or absent.
Readings of pen and
display do not
match exactly.
Und
Out of calibration
or
Questionable accuracy
Ovr
Prb
Factory Service and Returns
We recommend that damaged instruments be
returned to our factory for complete repair. Before
returning any instrument or package, please call for
a Return Authorization (RA) number. When calling,
please have the following information available:
1.
P.O. number for out-of-warranty units.
2.
Serial number of unit.
The Dickson Warranty
Dickson warrants the KT6 line of instruments will be
free from defects in material and workmanship or
accidental damage for a period of twelve months
after delivery. In the event of a claim under this
warranty, the product or part must be returned
to the factory for repair or replacement (shipping
prepaid) with a Return Authorization Number (See
repair information above). It will be repaired or
replaced at Dickson's option without charge.
This warranty does not cover routine calibration,
Dickson manufactures a complete line of temperature, humidity, air quality &
pressure instruments. Send or call for a free catalog of Dickson products
24-hour Chart
C652
C654
C654
C656
C658
C658
C660
C662
Cause
Tip too sharp, cartridge
dried out.
Wrong Chart
Pen not on properly
Line thickness
Below range of recorder
Harsh environments,
stressful conditions,
or time.
Above range of recorder
Probe missing
3.
4.
Clearly mark the RA number on the outside
of the package and return the instrument,
shipping prepaid. Delivery will be refused for
packages sent without RA numbers.
pen, chart and battery replacement.
The foregoing warranty and remedy are exclusive
and in lieu of all other warranties either expressed
or implied. Dickson shall not be liable for conse-
quential or incidental damages resulting from failure
or malfunction of its products. Dickson makes no
warranty for products not manufactured by it or
for any products modified by buyer, or subject to
misuse or neglect.
8
7-day Chart
C651
C653
C653
C655
C657
C657
C659
C661
Check/Remedy
Sand tip, moisten or replace pen.
CHECK DIP SWITCH #4,5,6
Push pen completely onto pen arm.
Check to see that proper chart is
installed.
Check temperature range
See Calibration Procedure on p.8
or
return to factory for recalibration.
Check temperature range
Plug K-thermocouple into back of the
recorder (See diagram on pg. 3)
Model number of unit.
The problem you're experiencing with unit.
P222
P246
A203
D163
D164
R013
D605
D608
D617
A202
N100
N300
E100