SPEED
HIGH
MED-HIGH
MED-LOW
LOW
SPEED
HIGH
MED-HIGH
MED-LOW
LOW
SPEED
HIGH
MED-HIGH
MED-LOW
LOW
LOCATION
SIDES
BACK
TOP
BOTTOM
FLUE PIPE
FRONT
12
Air delivery - CFM with air filter
0.2" (W.C.)
1425
1130
840
725
0.2" (W.C.)
2080
1892
1556
1221
0.2" (W.C.)
1650
1450
1215
850
Minimum clearances - combustible materials
APPLICATION
FURNACE
SUPPLY PLENUM WITHIN 1.8 M (6') OF FURNACE
ACCESS PANEL TO BLOWER
FURNACE OR PLENUM
HORIZONTAL WARM AIR DUCT WITHIN 1.8 m (6') OF FURNACE
FURNACE (COMBUSTIBLE FLOOR)
HORIZONTALLY OR BELOW FLUE PIPE
VERTICALLY ABOVE FLUE PIPE
FURNACE
TABLE 4
AMT75 to AMT105 (1/3 HP MOTOR)
EXTERNAL STATIC PRESSURE WITH AIR FILTER
0.3" (W.C.)
1350
1045
810
730
AMT120 to AMT155 (3/4 HP MOTOR)
EXTERNAL STATIC PRESSURE WITH AIR FILTER
0.3" (W.C.)
2041
1859
1475
1164
AMT120 to AMT155 (1/3 HP MOTOR)
EXTERNAL STATIC PRESSURE WITH AIR FILTER
0.3" (W.C.)
1600
1360
1180
845
TABLE 5
0.4" (W.C.)
0.5" (W.C.)
1305
1000
770
740
0.4" (W.C.)
0.5" (W.C.)
1965
1770
1394
1081
0.4" (W.C.)
0.5" (W.C.)
1560
1305
1130
840
CLEARANCES
RECOMMENDED
(com bustible
ACCESS FOR SERVICE
m aterials)
2.54 cm (1")
2.54 cm (1")
10.16 cm (4")
50.8 mm (2")
50.8 mm (2")
0"
10.16 cm (4")
22.86 cm (9")
20.32 cm (8")
1250
950
740
745
1864
1675
1318
998
1510
1250
1100
840
0.6 m (24")
0.6 m (24")
0.6 m (24")