Note: Should you see droplets (or other signs of dampness) on or around the
unit, this is condensed water from the humidifier. This means that the air can
no longer absorb the moisture from the humidifier. Please turn the output
down so that droplets are no longer visible.
Cleaning
Before each piece of maintenance and after every use, turn off the unit and
remove the plug from the plug socket. Before you clean Anton, the power
adapter (16) must be separated from the power adapter connection (17).
Attention: Never submerge the unit in water (danger of short circuiting).
• To clean the outside, wipe with a damp cloth and then dry well.
• To clean the inside, remove the water tank (2), the mist outlet (1), the mist
chamber (5) and the silver cube (8). Then you can clean the ultrasonic
membrane with a normal household decalcifier. It is important during this
that the level of water inside the unit does not go higher than 10 mm.
Should the level of water accidentally exceed 10 mm, contact Stadler
Form or a specialist technician immediately. Should not all residues be
able to be removed, then you can clean the ultrasonic membrane with the
help of the cleaning brush (front or reverse side). Please do not scrape the
membrane with a hard object. With persistent calcification, we recom-
mend that you decalcify the unit several times in a row. After decalcify-
ing, rinse the lower part and then dry thoroughly.
• To clean the water tank, rinse it out with warm water. Should calcification
be visible, you can also decalcify the water tank. Afterwards, rinse out the
water tank and then dry.
Replacement of the anticalc cartridge
• Please find the recommended replacement intervals in the table (see «Be-
fore setup»).
• Tip: The efficiency of the cartridge can be inspected with a simple test.
Hold a small mirror in the mist for a few seconds. If there are then white de-
posits (calcium carbonate) on the mirror, then the cartridge needs changing.
• The anticalc cartridge is located on the inner side of the tank cap. First
screw the tank cap off the water tank and then screw the cartridge from
the tank cap. Dispose of the cartridge in the domestic waste. Soak the an-
ticalc cartridge in a water bath for 24 hours before the first use (not in the
water tank!). The resin has to absorb water to reach high performance.
• Keep the tank cap when replacing the cartridge!
Silver Cube ™
The silver cube (8) prevents the growth of germs and bacteria in the hu-
midifier due to the continuous release of silver ions. The use of a silver cube
leads to a hygienic room climate. The lifetime of the silver cube is around
one year. We therefore recommend that you replace the silver cube at the
beginning of every humidifying season. The silver cube starts working as
soon as it comes into contact with water, and also works when the unit is
switched off.
Repairs
• Repairs to electrical appliances must only be carried out by a qualified
electrical technician. If improper repairs are carried out, the warranty
lapses and all liability is refused.