Terminal
Description
1
Voltage supply for synchronization (L1)
2
Not used
3
Voltage Supply for synchronization (L2)
4
Not used
5
24Vdc - Auxiliary supply and Fan supply
6
24Vdc + Auxiliary supply and Fan supply
7
Not used
8
COM I - Common Digital Input
9
+ Input command signal SSR, 0-10V, 4-20mA, POT
10
- Input command signal SSR, 0-10V, 4-20mA, POT
Terminal
Description
11
0V GND
12
Output +10Vdc stabilized 1 mA MAX
13
Not used
14
Not used
15
DI1 - Configurable Input
16
DA2 - Enable Digital Input
17
Not used
18
NC - Normally Close contact alarm relay output (HB)
19
C - Common contact alarm relay output
20
NO - Normally Open contact alarm relay output (HB)
19