Quick Install Guide
How-to videos
lutron.com/wiringwizard
MACL-LFQ
CFL
LED
LFCA
DEL
AFC
75 W
250 W
LED / CFL
Incand. / Hal.
1.5 A
Fan
Please read before installing
English
WARNING: SHOCK HAZARD. May result in serious injury or death.
Turn off power at circuit breaker or fuse before installing.
Yellow
Red
Screw
Terminal
Green
AFTER INSTALLATION: Adjust dimming range for LEDs and CFLs
A
Hold
and
until
an indicator light (IL)
blinks on the dimmer.
IL
&
FASS
Pull tab out for bulb replacement.
Limited Warranty: www.lutron.com/TechnicalDocumentLibrary/369-119_Wallbox_Warranty.pdf
Lutron, FASS and LED+ are trademarks or registered trademarks of Lutron Electronics Co., Inc., in the U.S. and other countries.
The YouTube icon is a trademark of Google LLC.
Receive an Extended Warranty: www.lutron.com/CLregistration
Support: 1.844.LUTRON1 (USA / Canada)
LED + Dimmer
Use included diagrams
or visit our website for
step-by-step instructions.
Ganging and Derating
Remove side sections if
mounting 2 or more devices side
by side. No derating is required
when ganging this product.
INSTALL WITH CONFIDENCE
VIDEO & STEP-BY-STEP INSTRUCTIONS
VIDEO & STEP-BY-STEP INSTRUCTIONS
lutron.com/wiringwizard
Tags
Fan
Light
Tag
Line / Hot
Ground (green or bare)
B
Use
improve lowest dimming
level.
Double-tap to turn lights
on to full intensity.
Press & hold for delayed
fade-to-off.
Double-tap to turn fan
on to full speed.
120 V~ 60 Hz
Install with
confidence
Keep
Remove
Bend back
and forth
Connect
or
to
OR
Operation
Error blink codes
LEDs Blinking
Top and Bottom LED (as shown at left)
Top and 2nd from Bottom LED
Top and 3rd from Bottom LED
For Troubleshooting, please visit www.lutron.com/support
For advanced programming instructions, please see Lutron Application
Note #669 on www.lutron.com/support
©2013–2021 Lutron Electronics Co., Inc.
+1.888.235.2910 (Mexico)
®
Find the right LED
lutron.com/LEDfinder
Important Notes
1. Do not use with exhaust fans.
2. Do not use with fans having integrated remote controls.
3. Use MACL-LFQ control with only one ceiling paddle fan per
control. Not for use with DC motor fans.
4. CAUTION: Use only with permanently installed ceiling fan
fixtures with screw-in compact fluorescent, screw-in LED,
halogen, or incandescent lamps. To avoid overheating
and possible damage to other equipment, do not use to
control receptacles, motor-driven appliances, or low-voltage
transformer-supplied appliances.
5. Install in accordance with all national and local electrical codes.
6. When no "grounding means" exists in wallbox, the 2011
National Electrical CodeR (NECR) allows a control to be installed
as a replacement if 1) a nonmetallic, noncombustible faceplate
is used with non-metallic attachment screws or 2) the circuit
is protected by a ground fault circuit interrupter (GFCI). When
installing a control according to these methods, cap or remove
green wire before screwing control into wallbox and use an
appropriate faceplate such as Claro or Satin Colors series
wallplates by Lutron.
7. For indoor use only between 32 °F and 104 °F (0 °C and
40 °C).
8. Clean dimmers with a soft damp cloth only. Do not use any
chemical cleaners.
Before Removing the Old Switch:
Place a single tag on the wire that
is connected to the Line/Hot side
of the switch (the side with the tab).
Place two tags on the wire that is
connected to the switch controlling
the fan.
5 in-lbs (0,55 N•m)
A
OR
12 / 14 AWG
(2.5 – 1.5 mm
)
2
Turn lights off and on at lowest
C
level to confirm operation.
Error Description
Light's circuit is short circuited
Temperature is too high, lamp
wattage too high
Light pull chain in off state or all
the lamps are blown out
P/N 0301993 REV A
B
14 AWG ONLY
(1.5 mm
)
2
1/2 in
(13 mm)